GASKET,SHEET,12IN,300#,GR/304
Material 4100014119 · GASKET · Plant 1000
ASafety-criticalMonitorHealthy
- Material
- 4100014119
- Category
- GASKET
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (39 of 69 FuncLocs A/B, 11 safety/shutdown valve)
- Supplier
- SURYA INSTRUMEN MAKMUR PT
- Lead time
- 69 d · P80 89 d
- Unit price
- Rp 160,462
Recommendation
- 1.Safety-critical element: installed on 11 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 100 EA/year: 97 unplanned (recency-weighted compound poisson (own history)) + 3.6 from the maintenance plan.
- 3.Lead time ~69 days; expected demand during lead time 19 (incl. 0.7 planned).
- 4.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 68, order up to 165.
- 5.Installed on 69 FuncLoc(s), 39 of them criticality A/B.
- 6.ML early warning: 100% probability of demand in the next 90 days.
Safety-critical (SCE)ML early warningLast turnaround used 42Single sourceAbnormal consumptionOpen POPlanned demand in lead time
On hand / on order
49 / 201
next delivery 14 Nov 2026
Today Min / Max
15 / 34
static parameters in BoM
Rec. Min (reorder point)
68
safety stock 50
Rec. Max
165
order qty 97
Service level
99.9%
stockout risk now 0%
Unit price
Rp 160,462
PO history
ML early warning: 100% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 13 issue days in the last 180 days, last issue 7 days ago, 65 failure notifications on its equipment in 90 days, 1 planned jobs in 90 days, 7 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (50 units) excluded from the baseline.
Demand pattern Erratic · 34 issue days · 1 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 8.6B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~15 days.
Installed on 69 functional locations
39 with criticality A/B · 86 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_BF-105 CRACKING FURNACE BF-105 | A | 1 | 114 | 42.86 |
| PX_BF-103 CRACKING FURNACE BF-103 | A | 1 | 38 | 14.58 |
| PX_BF-109 CRACKING FURNACE BF-109 | A | 1 | 29 | 11.58 |
| PX_KT-419A TURBINE FOR KC-419A | A | 1 | 6 | 2.81 |
| PX_HE-388A CHARGE GAS EXCHANGER | A | 1 | 5 | 1.93 |
| PX_KC-316D METHANOL FAN | A | 1 | 5 | 1.43 |
| PX_KT-397A TURBINE FOR KC-397A | A | 2 | 5 | 2.81 |
| PX_PP-1192 FEED PUMP | A | 1 | 5 | 1.47 |
| PX_PP-1396A CAUSTIC PUMP | A | 1 | 5 | 1.47 |
| PX_TCV-515 TEMPERATURE CONTROL VALVE | A | 1 | 5 | 1.83 |
| PX_HE-848C COOLING WATER CONDENSER | A | 1 | 4 | 1.08 |
| PX_KC-671D FEED BLOWER | A | 1 | 3 | 1.00 |
Lead time and procurement
Lead time 69 ± 46 days (PO history, 21 PO lines) · on-time 34%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 11 Sept 2026 | PR03 Regular replenishment | 63 | Rp 167,756 | 26 Nov 2026 open | 76 d |
| 03 Sept 2026 | PR05 Project / turnaround | 25 | Rp 155,309 | 08 Feb 2027 open | 158 d |
| 01 Sept 2026 | PR03 Regular replenishment | 41 | Rp 162,831 | 14 Nov 2026 open | 74 d |
| 15 Aug 2026 | PR03 Regular replenishment | 33 | Rp 155,001 | 25 Sept 2026 | 41 d |
| 02 Jul 2026 | PR03 Regular replenishment | 33 | Rp 160,462 | 19 Aug 2026 | 48 d |
| 23 Jun 2026 | PR05 Project / turnaround | 72 | Rp 157,534 | 12 Jan 2027 open | 203 d |
| 18 Apr 2026 | PR03 Regular replenishment | 31 | Rp 168,290 | 28 May 2026 | 40 d |
| 22 Mar 2026 | PR01 Import / long-lead | 53 | Rp 156,945 | 01 Jun 2026 | 71 d |
| 24 Feb 2026 | PR03 Regular replenishment | 73 | Rp 167,627 | 03 Apr 2026 | 38 d |
| 15 Feb 2026 | PR06 Regular replenishment | 39 | Rp 166,742 | 04 Apr 2026 | 48 d |
Planned maintenance demand (next 12 months)
| Due | FuncLoc | Job | Qty |
|---|---|---|---|
| 01 Oct 2026 | PX_SDV-1988 | Final Element Overhaul; ONOFFV | 0.72 |
| 02 May 2027 | PX_PP-1213 | Pump overhaul | 2.15 |
| 02 Jul 2027 | PX_PP-1498C | Pump overhaul | 0.72 |
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 30 Sept 2026 | Low | PX_BF-103 | Leak from packing |
| 29 Sept 2026 | High | PX_BF-105 | Repair refractory crack BF-105 |
| 25 Sept 2026 | Medium | PX_BF-108 | Repair refractory crack BF-108 |
| 24 Sept 2026 | High | PX_BF-108 | Leak from packing |
| 24 Sept 2026 | Medium | PX_HE-388A | Replace lamp as per PM finding |
| 24 Sept 2026 | Low | PX_HE-848C | HE-848C fouling |
| 20 Sept 2026 | Medium | PX_BF-103 | Leak from packing |
| 20 Sept 2026 | Medium | PX_BF-105 | Replace lamp as per PM finding |
| 20 Sept 2026 | Medium | PX_BF-105 | Install scaffolding at BF-105 |
| 20 Sept 2026 | Medium | PX_BF-109 | Thermograph wall BF-109 |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 24 Sept 2026 | 1 | 201000008685 | Corrective |
| 23 Sept 2026 | 3 | 201000030211 | Corrective |
| 24 Aug 2026 | 1 | 201000039454 | Corrective |
| 09 Jul 2026 | 9 | 201000014705 | Corrective |
| 04 Jul 2026 | 4 | 201000035815 | Corrective |
| 30 Jun 2026 | 9 | 201000006253 | Corrective |
| 29 Jun 2026 | 2 | 201000006253 | Corrective |
| 29 Jun 2026 | 5 | 201000006253 | Corrective |
| 11 Jun 2026 | 4 | 201000028320 | Corrective |
| 10 Jun 2026 | 1 | 201000031705 | Corrective |
| 30 Apr 2026 | 2 | 201000020375 | Corrective |
| 20 Apr 2026 | 2 | 201000029249 | Corrective |
| 16 Apr 2026 | 1 | 201000025702 | Corrective |
| 13 Apr 2026 | 1 | 201000013543 | Corrective |
| 27 Mar 2026 | 1 | 204000036669 | Preventive |