GASKET,RING,8IN,300#,GRAPHITE
Material 4100014337 · GASKET · Plant 1000
ASafety-criticalMonitorHealthy
- Material
- 4100014337
- Category
- GASKET
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (10 of 17 FuncLocs A/B, 2 safety/shutdown valve)
- Supplier
- SAMUDRA SEJAHTERA INTERNASIONAL PT
- Lead time
- 28 d · P80 34 d
- Unit price
- Rp 1.2M
Recommendation
- 1.Safety-critical element: installed on 2 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 44 EA/year: 43 unplanned (recency-weighted compound poisson (own history)) + 0.7 from the maintenance plan.
- 3.Lead time ~28 days; expected demand during lead time 3.3.
- 4.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 18, order up to 42.
- 5.Installed on 17 FuncLoc(s), 10 of them criticality A/B.
- 6.ML early warning: 76% probability of demand in the next 90 days.
Safety-critical (SCE)ML early warningLast turnaround used 2Single sourceAbnormal consumptionOpen PO
On hand / on order
30 / 21
next delivery 04 Oct 2026
Today Min / Max
11 / 23
static parameters in BoM
Rec. Min (reorder point)
18
safety stock 15
Rec. Max
42
order qty 24
Service level
99.9%
stockout risk now 0%
Unit price
Rp 1.2M
PO history
ML early warning: 76% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 3 issue days in the last 180 days, last issue 22 days ago, 22 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 3 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (2 units) excluded from the baseline.
Demand pattern Lumpy · 10 issue days · 1 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 3.1B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~15 days.
Installed on 17 functional locations
10 with criticality A/B · 20 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_BF-102 CRACKING FURNACE BF-102 | A | 1 | 71 | 28.72 |
| PX_KT-856A TURBINE FOR KC-856A | A | 1 | 7 | 2.81 |
| PX_KC-479C DILUTION STEAM COMPRESSOR | A | 1 | 5 | 2.71 |
| PX_HE-1393C QUENCH WATER PREHEATER | A | 1 | 3 | 1.08 |
| PX_KC-464A CONDENSATE BLOWER | A | 1 | 2 | 1.43 |
| PX_SDV-554B CHARGE GAS ISOLATION | A | 1 | 1 | 0.06 |
| PY_VD-953B METHANOL DRUM | A | 1 | 1 | 0.51 |
| PX_PP-1325 BFW PUMP | B | 1 | 5 | 1.90 |
| PX_HE-695A METHANOL TLE | B | 4 | 2 | 1.08 |
| PX_PP-657C SEAL OIL PUMP | B | 1 | 0 | 0.19 |
| PX_HE-1727 LUBE OIL COOLER | C | 1 | 3 | 1.08 |
| PX_HE-1715D DILUTION STEAM REBOILER | C | 1 | 0 | 0.22 |
Lead time and procurement
Lead time 28 ± 12 days (PO history, 6 PO lines) · on-time 41%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 05 Sept 2026 | PR03 Regular replenishment | 21 | Rp 1.1M | 04 Oct 2026 open | 29 d |
| 30 Jul 2026 | PR06 Regular replenishment | 20 | Rp 1.1M | 10 Aug 2026 | 11 d |
| 03 May 2026 | PR06 Regular replenishment | 25 | Rp 1.2M | 28 May 2026 | 25 d |
| 18 Jul 2025 | PR03 Regular replenishment | 7 | Rp 1.1M | 21 Aug 2025 | 34 d |
| 03 Jul 2025 | PR03 Regular replenishment | 16 | Rp 1.2M | 10 Aug 2025 | 38 d |
| 22 May 2025 | PR03 Regular replenishment | 22 | Rp 1.2M | 12 Jun 2025 | 21 d |
Planned maintenance demand (next 12 months)
| Due | FuncLoc | Job | Qty |
|---|---|---|---|
| 07 Jul 2027 | PX_KC-505D | Compressor major overhaul | 0.72 |
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 23 Sept 2026 | Low | PX_BF-102 | Replace burner tip BF-102 |
| 10 Sept 2026 | Medium | PX_KC-479C | KC-479C bearing temp high |
| 07 Sept 2026 | Low | PX_BF-102 | Thermograph wall BF-102 |
| 06 Sept 2026 | Medium | PX_BF-102 | Decoking follow up BF-102 |
| 03 Sept 2026 | Medium | PX_BF-102 | Replace lamp as per PM finding |
| 30 Aug 2026 | High | PX_BF-102 | Painting BF-102 |
| 27 Aug 2026 | Medium | PX_BF-102 | Decoking follow up BF-102 |
| 26 Aug 2026 | Medium | PX_HE-1393C | HE-1393C tube leak |
| 23 Aug 2026 | High | PX_HE-1393C | Replace lamp as per PM finding |
| 18 Aug 2026 | Low | PX_KC-479C | Leak from packing |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 09 Sept 2026 | 3 | 201000021806 | Corrective |
| 03 Aug 2026 | 1 | 201000029979 | Corrective |
| 26 Jul 2026 | 2 | 201000003691 | Corrective |
| 14 Feb 2026 | 7 | 201000013371 | Corrective |
| 10 Jan 2026 | 3 | 201000015307 | Corrective |
| 09 Jan 2026 | 2 | 201000028812 | Corrective |
| 31 Dec 2025 | 4 | 201000028354 | Corrective |
| 15 Dec 2025 | 2 | 201000009093 | Corrective |
| 15 Dec 2025 | 5 | 201000029708 | Corrective |
| 06 Dec 2025 | 4 | 201000033371 | Corrective |
| 07 Nov 2025 | 2 | 203000026396 | Turnaround |
| 20 May 2025 | 13 | 201000023546 | Corrective |