GASKET,SW,2IN,150#,PTFE
Material 4100014709 · GASKET · Plant 1000
ASafety-criticalReorderCriticalStockout
- Material
- 4100014709
- Category
- GASKET
- Base unit
- EA
- MRP type
- Non Stock
- Criticality
- A (6 of 10 FuncLocs A/B, 2 safety/shutdown valve)
- Supplier
- SURYA INSTRUMEN MAKMUR PT
- Lead time
- 23 d · P80 24 d
- Unit price
- Rp 1.6M
Recommendation
- 1.Safety-critical element: installed on 2 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 7.6 EA/year: 7.6 unplanned (credibility blend: own history + installed-base prior).
- 3.Lead time ~23 days; expected demand during lead time 0.5.
- 4.A 100.0% service level gives the lowest holding + downtime-risk cost: reorder at 7, order up to 15.
- 5.On hand 0 + on order 0 is at or below the reorder point: order 15 now.
- 6.Installed on 10 FuncLoc(s), 6 of them criticality A/B.
Proposed purchase requisition
15 EA
Rp 24.1M · order by 01 Oct 2026
Expected arrival ≈ 23 days
Safety-critical (SCE)Convert to Stock ItemLast turnaround used 12Single source
On hand / on order
0 / 0
no open PO
Today Min / Max
0 / 0
static parameters in BoM
Rec. Min (reorder point)
7
safety stock 7
Rec. Max
15
order qty 8
Service level
100.0%
stockout risk now 13%
Unit price
Rp 1.6M
PO history
ML early warning: 18% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue 271 days ago, 1 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (12 units) excluded from the baseline.
Demand pattern Lumpy · 4 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 747.4M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~15 days.
Installed on 10 functional locations
6 with criticality A/B · 14 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_KT-419A TURBINE FOR KC-419A | A | 3 | 6 | 2.81 |
| PX_HE-1074 C3 RECYCLE REBOILER | A | 1 | 3 | 1.08 |
| PX_HE-232C ETHYLENE PREHEATER | A | 1 | 0 | 0.22 |
| PX_HE-301B FUEL OIL REBOILER | A | 2 | 0 | 0.22 |
| PX_KC-669 DEMIN WATER BLOWER | A | 1 | 0 | 0.57 |
| PX_HE-1647D BOTTOM COOLER | B | 1 | 0 | 0.22 |
| PX_4-MS-25646-A22A-HS PIPE-4 FROM KC-155D TO PP-304 | C | 1 | 0 | 0.01 |
| PX_BF-101 CRACKING FURNACE BF-101 | S | 2 | 8 | 3.02 |
| PX_PRV-1448 SAFETY VALVE PP-752B | S | 1 | 0 | 0.04 |
| PX_PRV-182B SAFETY VALVE PP-700 | S | 1 | 0 | 0.04 |
Lead time and procurement
Lead time 23 ± 12 days (PO history, 5 PO lines) · on-time 34%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 19 Mar 2026 | PR06 Regular replenishment | 6 | Rp 1.6M | 31 Mar 2026 | 12 d |
| 26 Oct 2025 | PR06 Regular replenishment | 8 | Rp 1.6M | 13 Nov 2025 | 18 d |
| 14 Jul 2025 | PR06 Regular replenishment | 8 | Rp 1.6M | 19 Jul 2025 | 5 d |
| 03 Jul 2025 | PR05 Project / turnaround | 5 | Rp 1.6M | 03 Aug 2025 | 31 d |
| 17 May 2025 | PR03 Regular replenishment | 6 | Rp 1.7M | 08 Jun 2025 | 22 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 14 Sept 2026 | Medium | PX_BF-101 | Replace lamp as per PM finding |
| 16 Aug 2026 | Medium | PX_BF-101 | Install scaffolding at BF-101 |
| 02 Jul 2026 | Low | PX_HE-1074 | Install scaffolding at HE-1074 |
| 22 Jun 2026 | Low | PX_BF-101 | Thermograph wall BF-101 |
| 06 Jun 2026 | Emergency | PX_BF-101 | Decoking follow up BF-101 |
| 03 Apr 2026 | Medium | PX_KT-419A | KT-419A steam leak at gland |
| 22 Mar 2026 | Low | PX_HE-1074 | Cleaning HE-1074 |
| 17 Mar 2026 | Medium | PX_KT-419A | Install cover plate for MCP cracking |
| 27 Nov 2025 | Medium | PX_BF-101 | Peep door broken BF-101 |
| 20 Nov 2025 | Medium | PX_KT-419A | Leak from packing |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 03 Jan 2026 | 2 | 201000008094 | Corrective |
| 03 Jan 2026 | 4 | 201000031670 | Corrective |
| 31 Dec 2025 | 1 | 201000038032 | Corrective |
| 14 Nov 2025 | 4 | 203000023445 | Turnaround |
| 05 Nov 2025 | 8 | 203000029164 | Turnaround |
| 07 Aug 2025 | 5 | 201000002003 | Corrective |
| 11 Jun 2025 | 1 | 201000027597 | Corrective |