GASKET,RING,10IN,600#,PTFE
Material 4100015570 · GASKET · Plant 1000
BReorderNormalBelow reorder point
- Material
- 4100015570
- Category
- GASKET
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- B (2 of 6 FuncLocs A/B)
- Supplier
- No PO history
- Lead time
- 31 d · P80 51 d
- Unit price
- Rp 214,454 (est.)
Recommendation
- 1.Forecast 24 EA/year: 24 unplanned (credibility blend: own history + installed-base prior).
- 2.Lead time ~31 days; expected demand during lead time 2.0.
- 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 17, order up to 42.
- 4.On hand 5 + on order 0 is at or below the reorder point: order 37 now.
- 5.Installed on 6 FuncLoc(s), 2 of them criticality A/B.
Proposed purchase requisition
37 EA
Rp 7.9M · order by 01 Oct 2026
Expected arrival ≈ 31 days
Price estimatedLead time estimated
On hand / on order
5 / 0
no open PO
Today Min / Max
2 / 6
static parameters in BoM
Rec. Min (reorder point)
17
safety stock 15
Rec. Max
42
order qty 25
Service level
99.9%
stockout risk now 31%
Unit price
Rp 214,454
Category + unit estimate
ML early warning: 4% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 1 issue days in the last 180 days, last issue 1 days ago, 7 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Lumpy · 2 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 356.3M/yr in expected downtime and emergency buys. A stockout here stops production with probability 0.53% for ~15 days.
Installed on 6 functional locations
2 with criticality A/B · 7 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_HE-1756B SLOP OIL CONDENSER | B | 1 | 13 | 4.50 |
| PX_VD-679 QUENCH WATER KO DRUM | B | 2 | 0 | 0.08 |
| PX_KT-447 TURBINE FOR KC-447 | S | 1 | 13 | 6.24 |
| PX_KC-422A C4 PRODUCT BLOWER | S | 1 | 6 | 2.71 |
| PX_CL-1510 CONDENSATE STRIPPER | S | 1 | 2 | 1.23 |
| PX_CL-899 SLOP OIL COLUMN | S | 1 | 0 | 0.38 |
Lead time and procurement
Lead time 31 ± 16 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 23 Sept 2026 | Low | PX_HE-1756B | HE-1756B tube leak |
| 01 Sept 2026 | Low | PX_KT-447 | Replace lamp as per PM finding |
| 06 Aug 2026 | Medium | PX_CL-1510 | Replace lamp as per PM finding |
| 14 Jul 2026 | Medium | PX_HE-1756B | Retubing HE-1756B |
| 10 Jul 2026 | Low | PX_HE-1756B | HE-1756B tube leak |
| 08 Jul 2026 | Medium | PX_KC-422A | KC-422A high vibration |
| 08 Jul 2026 | Medium | PX_KT-447 | Replace lamp as per PM finding |
| 13 May 2026 | Low | PX_KT-447 | KT-447 trip test |
| 09 May 2026 | Medium | PX_HE-1756B | Retubing HE-1756B |
| 01 May 2026 | Low | PX_HE-1756B | [MSI-B-26-TTX-189/M] Replace line |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 30 Sept 2026 | 1 | 201000018328 | Corrective |
| 25 Jan 2026 | 10 | 201000033106 | Corrective |