GASKET,SHEET,3/4IN,300#,GRAPHITE
Material 4100015601 · GASKET · Plant 1000
AReorderCriticalStockout
- Material
- 4100015601
- Category
- GASKET
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (2 of 5 FuncLocs A/B)
- Supplier
- No PO history
- Lead time
- 31 d · P80 51 d
- Unit price
- Rp 214,454 (est.)
Recommendation
- 1.Forecast 6.2 EA/year: 6.2 unplanned (credibility blend: own history + installed-base prior).
- 2.Lead time ~31 days; expected demand during lead time 0.5.
- 3.A 100.0% service level gives the lowest holding + downtime-risk cost: reorder at 6, order up to 13.
- 4.On hand 0 + on order 0 is at or below the reorder point: order 13 now.
- 5.Installed on 5 FuncLoc(s), 2 of them criticality A/B.
Proposed purchase requisition
13 EA
Rp 2.8M · order by 01 Oct 2026
Expected arrival ≈ 31 days
Price estimatedLead time estimated
On hand / on order
0 / 0
no open PO
Today Min / Max
1 / 2
static parameters in BoM
Rec. Min (reorder point)
6
safety stock 6
Rec. Max
13
order qty 7
Service level
100.0%
stockout risk now 23%
Unit price
Rp 214,454
Category + unit estimate
ML early warning: 6% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 1 issue days in the last 180 days, last issue 107 days ago, 3 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Single issue · 1 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 1.0B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~15 days.
Installed on 5 functional locations
2 with criticality A/B · 5 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_PP-506A COOLING WATER PUMP | A | 1 | 23 | 8.76 |
| PX_PP-1882C RECYCLE ETHANE PUMP | A | 1 | 2 | 0.62 |
| PX_LCV-174 LEVEL CONTROL VALVE | C | 1 | 0 | 0.12 |
| PX_PCV-1956A HE-1483A PRESSURE CONTROL | C | 1 | 0 | 0.08 |
| PX_PCV-1276 PP-1899 PRESSURE CONTROL | S | 1 | 0 | 0.08 |
Lead time and procurement
Lead time 31 ± 16 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 11 Sept 2026 | Low | PX_PP-506A | PP-506A high vibration |
| 09 Sept 2026 | Medium | PX_PP-506A | Replace lamp as per PM finding |
| 01 Aug 2026 | Medium | PX_PP-506A | Oil leak at PP-506A bearing housing |
| 20 Jun 2026 | Medium | PX_PP-506A | Replace lamp as per PM finding |
| 11 Jun 2026 | Low | PX_PP-506A | Leak from packing |
| 30 May 2026 | Low | PX_PP-506A | Install scaffolding at PP-506A |
| 28 May 2026 | Medium | PX_PP-506A | PP-506A discharge pressure low |
| 19 May 2026 | Medium | PX_PP-506A | PP-506A discharge pressure low |
| 12 Apr 2026 | Medium | PX_PP-506A | Overhaul PP-506A |
| 31 Mar 2026 | Low | PX_PP-506A | Replace lamp as per PM finding |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 16 Jun 2026 | 2 | 201000028015 | Corrective |