Sparely
DU

GASKET,SW,1IN,150#,GR/304

Material 4100017788 · GASKET · Plant 1000

AReduceNon-moving
Material
4100017788
Category
GASKET
Base unit
EA
MRP type
Stock Item
Criticality
A (2 of 4 FuncLocs A/B)
Supplier
No PO history
Lead time
31 d · P80 51 d
Unit price
Rp 214,454 (est.)

Recommendation

  • 1.Forecast 0.5 EA/year: 0.5 unplanned (installed-base failure prior (no history)).
  • 2.Lead time ~31 days; expected demand during lead time 0.0.
  • 3.A 100.0% service level gives the lowest holding + downtime-risk cost: reorder at 4, order up to 8.
  • 4.Stock 11 exceeds the level to keep (8) by 3.
  • 5.Installed on 4 FuncLoc(s), 2 of them criticality A/B.
Price estimatedLead time estimated
On hand / on order
11 / 0
no open PO
Today Min / Max
2 / 6
static parameters in BoM
Rec. Min (reorder point)
4
safety stock 4
Rec. Max
8
order qty 4
Service level
100.0%
stockout risk now 0%
Unit price
Rp 214,454
Category + unit estimate
ML early warning: 4% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue never, 2 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.

Consumption history and 12-month forecast

Units per month. Turnaround issues (0 units) excluded from the baseline.

Demand pattern No demand · 0 issue days · method: Installed-base failure prior (no history).

Cost of each service level

Annual holding vs downtime-risk cost for this part

Not stocking at all would cost Rp 49.3M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~15 days.

Installed on 4 functional locations

2 with criticality A/B · 4 units installed

FuncLocCrit.InstalledNotificationsFailures / yr
PX_CL-894
COOLING WATER COLUMN
A110.38
PX_TCV-779C
PP-1798C TEMP CONTROL
A100.12
PX_LCV-1627D
LEVEL CONTROL VALVE
C100.12
PX_KC-458D
SLOP OIL FAN
S193.14

Lead time and procurement

Lead time 31 ± 16 days (Category estimate, 0 PO lines) · on-time –

No purchase history: price and lead time are estimated from parts of the same category.

Planned maintenance demand (next 12 months)

No part-consuming maintenance job uses this part in the next 12 months.

Recent notifications on its equipment

DatePriorityFuncLocDescription
19 Sept 2026MediumPX_KC-458DKC-458D lube oil filter DP high
16 Sept 2026LowPX_KC-458DKC-458D lube oil filter DP high
24 Jun 2026MediumPX_KC-458DKC-458D bearing temp high
15 Mar 2026MediumPX_KC-458DPainting KC-458D
27 Dec 2025MediumPX_KC-458DInstall scaffolding at KC-458D
09 Dec 2025MediumPX_KC-458DOverhaul
24 Nov 2025MediumPX_KC-458DKC-458D lube oil filter DP high
05 Sept 2025LowPX_KC-458DReplace lamp as per PM finding
21 May 2025MediumPX_KC-458DInspect coupling KC-458D
09 May 2025MediumPX_CL-894Replace lamp as per PM finding

Recent goods issues

Never issued in the 17-month history.