O-RING,VITON,24MM ID,5.3MM CS
Material 4100019372 · O-RING · Plant 1000
ASafety-criticalMonitorHealthy
- Material
- 4100019372
- Category
- O-RING
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (20 of 31 FuncLocs A/B, 4 safety/shutdown valve)
- Supplier
- GEMILANG SUPLINDO SENTOSA PT
- Lead time
- 31 d · P80 40 d
- Unit price
- Rp 20,269
Recommendation
- 1.Safety-critical element: installed on 4 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 177 EA/year: 176 unplanned (recency-weighted compound poisson (own history)) + 1.4 from the maintenance plan.
- 3.Lead time ~31 days; expected demand during lead time 15.
- 4.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 55, order up to 233.
- 5.Installed on 31 FuncLoc(s), 20 of them criticality A/B.
- 6.ML early warning: 100% probability of demand in the next 90 days.
Safety-critical (SCE)ML early warningLast turnaround used 48Single sourceAbnormal consumptionOpen PO
On hand / on order
180 / 172
next delivery 04 Oct 2026
Today Min / Max
47 / 146
static parameters in BoM
Rec. Min (reorder point)
55
safety stock 41
Rec. Max
233
order qty 178
Service level
99.9%
stockout risk now 0%
Unit price
Rp 20,269
PO history
ML early warning: 100% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 19 issue days in the last 180 days, last issue 1 days ago, 15 failure notifications on its equipment in 90 days, 2 planned jobs in 90 days, 8 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (92 units) excluded from the baseline.
Demand pattern Erratic · 65 issue days · 3 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 13.0B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~14 days.
Installed on 31 functional locations
20 with criticality A/B · 37 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PY_KC-419A PROPYLENE FAN | A | 1 | 19 | 5.71 |
| PX_KT-856A TURBINE FOR KC-856A | A | 1 | 7 | 2.81 |
| PX_KT-419A TURBINE FOR KC-419A | A | 1 | 6 | 2.81 |
| PX_KC-222B LEAN AMINE COMPRESSOR | A | 1 | 5 | 1.85 |
| PX_PP-139 CAUSTIC PUMP | A | 4 | 4 | 1.90 |
| PX_KC-778A CONDENSATE COMPRESSOR | A | 1 | 3 | 1.43 |
| PX_PP-207 INHIBITOR PUMP | A | 1 | 3 | 1.47 |
| PX_KC-235D DEMIN WATER FAN | A | 1 | 2 | 1.00 |
| PX_KT-460B TURBINE FOR KC-460B | A | 1 | 2 | 1.96 |
| PX_PP-1125B HYDROGEN PUMP | A | 1 | 2 | 0.62 |
| PX_PP-779A LUBE OIL PUMP | A | 1 | 2 | 0.62 |
| PX_KC-397A DILUTION STEAM FAN | A | 1 | 1 | 0.57 |
Lead time and procurement
Lead time 31 ± 17 days (PO history, 28 PO lines) · on-time 39%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 20 Sept 2026 | PR03 Regular replenishment | 172 | Rp 21,191 | 04 Oct 2026 open | 14 d |
| 27 Jul 2026 | PR06 Regular replenishment | 169 | Rp 20,981 | 12 Sept 2026 | 47 d |
| 08 Jun 2026 | PR03 Regular replenishment | 113 | Rp 19,887 | 30 Jun 2026 | 22 d |
| 05 Jun 2026 | PR03 Regular replenishment | 171 | Rp 19,732 | 20 Jun 2026 | 15 d |
| 11 May 2026 | PR03 Regular replenishment | 117 | Rp 19,510 | 31 May 2026 | 20 d |
| 08 May 2026 | PR03 Regular replenishment | 185 | Rp 20,961 | 18 Aug 2026 | 102 d |
| 02 May 2026 | PR03 Regular replenishment | 125 | Rp 20,461 | 12 Jun 2026 | 41 d |
| 15 Apr 2026 | PR03 Regular replenishment | 184 | Rp 20,749 | 04 May 2026 | 19 d |
| 29 Mar 2026 | PR03 Regular replenishment | 147 | Rp 19,962 | 15 Apr 2026 | 17 d |
| 05 Feb 2026 | PR04 Regular (other) | 120 | Rp 20,631 | 28 Feb 2026 | 23 d |
Planned maintenance demand (next 12 months)
| Due | FuncLoc | Job | Qty |
|---|---|---|---|
| 01 Nov 2026 | PX_KC-235D | Compressor major overhaul | 0.72 |
| 26 Dec 2026 | PX_KT-264A | Turbine major overhaul | 0.72 |
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 30 Sept 2026 | Medium | PX_PP-1892B | Replace lamp as per PM finding |
| 28 Sept 2026 | High | PY_KC-419A | Overhaul |
| 23 Sept 2026 | Medium | PX_PP-1892B | PP-1892B abnormal noise |
| 23 Sept 2026 | Medium | PY_KC-419A | Inspect coupling KC-419A |
| 18 Sept 2026 | Medium | PX_KT-202 | Repair insulation KT-202 |
| 18 Sept 2026 | Medium | PY_KC-419A | Install scaffolding at KC-419A |
| 01 Sept 2026 | High | PX_KC-582B | KC-582B high vibration |
| 31 Aug 2026 | Medium | PY_KC-419A | Install cover plate for MCP cracking |
| 28 Aug 2026 | Medium | PY_KC-419A | Install scaffolding at KC-419A |
| 26 Aug 2026 | Low | PX_KC-582B | Painting KC-582B |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 30 Sept 2026 | 1 | 201000000813 | Corrective |
| 13 Sept 2026 | 12 | 201000022973 | Corrective |
| 28 Aug 2026 | 3 | 201000028982 | Corrective |
| 14 Aug 2026 | 5 | 201000011746 | Corrective |
| 29 Jul 2026 | 3 | 201000005074 | Corrective |
| 29 Jul 2026 | 12 | 203000004330 | Turnaround |
| 28 Jul 2026 | 4 | 201000037932 | Corrective |
| 26 Jul 2026 | 4 | 203000004330 | Turnaround |
| 25 Jul 2026 | 2 | 203000004330 | Turnaround |
| 22 Jul 2026 | 2 | 201000023160 | Corrective |
| 18 Jul 2026 | 3 | 201000015470 | Corrective |
| 13 Jul 2026 | 4 | 201000013975 | Corrective |
| 06 Jul 2026 | 1 | 201000029242 | Corrective |
| 05 Jul 2026 | 3 | 204000019293 | Preventive |
| 19 Jun 2026 | 2 | 201000039950 | Corrective |