STUDBOLT,3/4INX40MM,B7/2H
Material 4100024258 · STUDBOLT · Plant 1000
ASafety-criticalMonitorHealthy
- Material
- 4100024258
- Category
- STUDBOLT
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (32 of 45 FuncLocs A/B, 3 safety/shutdown valve)
- Supplier
- GEMILANG LOGAM MAKMUR PT
- Lead time
- 27 d · P80 39 d
- Unit price
- Rp 18,102
Recommendation
- 1.Safety-critical element: installed on 3 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 897 EA/year: 897 unplanned (recency-weighted compound poisson (own history)).
- 3.Lead time ~27 days; expected demand during lead time 66.
- 4.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 250, order up to 1,113.
- 5.Installed on 45 FuncLoc(s), 32 of them criticality A/B.
- 6.ML early warning: 100% probability of demand in the next 90 days.
Safety-critical (SCE)ML early warningLast turnaround used 336Single sourceAbnormal consumptionOpen PO
On hand / on order
416 / 257
next delivery 03 Oct 2026
Today Min / Max
314 / 591
static parameters in BoM
Rec. Min (reorder point)
250
safety stock 184
Rec. Max
1,113
order qty 863
Service level
99.9%
stockout risk now 0%
Unit price
Rp 18,102
PO history
ML early warning: 100% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 13 issue days in the last 180 days, last issue 10 days ago, 60 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 6 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (480 units) excluded from the baseline.
Demand pattern Erratic · 30 issue days · 9 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 5.4B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~10 days.
Installed on 45 functional locations
32 with criticality A/B · 576 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_BF-105 CRACKING FURNACE BF-105 | A | 12 | 114 | 42.86 |
| PX_BF-112 CRACKING FURNACE BF-112 | A | 24 | 73 | 27.01 |
| PX_BF-103 CRACKING FURNACE BF-103 | A | 16 | 38 | 14.58 |
| PX_HE-1500B SEAL OIL CONDENSER | A | 12 | 7 | 3.22 |
| PX_KT-856A TURBINE FOR KC-856A | A | 4 | 7 | 2.81 |
| PX_KT-419A TURBINE FOR KC-419A | A | 24 | 6 | 2.81 |
| PX_KC-479C DILUTION STEAM COMPRESSOR | A | 20 | 5 | 2.71 |
| PX_KT-397A TURBINE FOR KC-397A | A | 8 | 5 | 2.81 |
| PX_PCV-1960 PRESSURE CONTROL VALVE | A | 8 | 4 | 0.94 |
| PX_HE-1393C QUENCH WATER PREHEATER | A | 16 | 3 | 1.08 |
| PX_CL-398 C3 RECYCLE TOWER | A | 4 | 2 | 0.38 |
| PX_KC-801 DEMIN WATER FAN | A | 8 | 2 | 1.43 |
Lead time and procurement
Lead time 27 ± 16 days (PO history, 13 PO lines) · on-time 41%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 19 Aug 2026 | PR06 Regular replenishment | 294 | Rp 18,124 | 08 Sept 2026 | 20 d |
| 29 Jul 2026 | PR06 Regular replenishment | 768 | Rp 17,819 | 20 Aug 2026 | 22 d |
| 26 Jul 2026 | PR03 Regular replenishment | 257 | Rp 17,578 | 03 Oct 2026 open | 69 d |
| 10 Jun 2026 | PR03 Regular replenishment | 808 | Rp 18,370 | 21 Jun 2026 | 11 d |
| 31 May 2026 | PR03 Regular replenishment | 762 | Rp 17,558 | 08 Jul 2026 | 38 d |
| 10 Apr 2026 | PR06 Regular replenishment | 285 | Rp 18,473 | 10 May 2026 | 30 d |
| 20 Mar 2026 | PR06 Regular replenishment | 421 | Rp 18,448 | 01 Apr 2026 | 12 d |
| 18 Mar 2026 | PR06 Regular replenishment | 835 | Rp 17,602 | 08 Apr 2026 | 21 d |
| 01 Dec 2025 | PR03 Regular replenishment | 583 | Rp 17,442 | 24 Dec 2025 | 23 d |
| 23 Sept 2025 | PR03 Regular replenishment | 645 | Rp 18,102 | 13 Oct 2025 | 20 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 30 Sept 2026 | Low | PX_BF-103 | Leak from packing |
| 30 Sept 2026 | Medium | PX_BF-112 | Install cover plate BF-112 |
| 29 Sept 2026 | High | PX_BF-105 | Repair refractory crack BF-105 |
| 29 Sept 2026 | Low | PX_BF-112 | Painting BF-112 |
| 28 Sept 2026 | Medium | PX_HE-771A | Retubing HE-771A |
| 27 Sept 2026 | Medium | PX_BF-112 | Repair insulation BF-112 |
| 20 Sept 2026 | Medium | PX_BF-103 | Leak from packing |
| 20 Sept 2026 | Medium | PX_BF-105 | Replace lamp as per PM finding |
| 20 Sept 2026 | Medium | PX_BF-105 | Install scaffolding at BF-105 |
| 19 Sept 2026 | Low | PX_BF-103 | Leak from packing |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 21 Sept 2026 | 8 | 201000019618 | Corrective |
| 22 Aug 2026 | 24 | 201000006257 | Corrective |
| 21 Aug 2026 | 8 | 201000013554 | Corrective |
| 30 Jul 2026 | 32 | 201000026316 | Corrective |
| 26 Jul 2026 | 8 | 201000005472 | Corrective |
| 13 Jul 2026 | 16 | 201000029732 | Corrective |
| 07 Jul 2026 | 8 | 201000030618 | Corrective |
| 25 Jun 2026 | 8 | 201000021992 | Corrective |
| 24 Jun 2026 | 8 | 201000016931 | Corrective |
| 03 Jun 2026 | 48 | 201000037251 | Corrective |
| 20 May 2026 | 96 | 201000006755 | Corrective |
| 22 Apr 2026 | 12 | 201000020310 | Corrective |
| 12 Apr 2026 | 4 | 201000013543 | Corrective |
| 15 Mar 2026 | 12 | 201000018051 | Corrective |
| 27 Feb 2026 | 24 | 201000027179 | Corrective |