STUDBOLT,1/2INX45MM,B7/2H
Material 4100024320 · STUDBOLT · Plant 1000
ASafety-criticalMonitorHealthy
- Material
- 4100024320
- Category
- STUDBOLT
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (20 of 30 FuncLocs A/B, 3 safety/shutdown valve)
- Supplier
- GEMILANG MANDIRI INTERNASIONAL PT
- Lead time
- 25 d · P80 40 d
- Unit price
- Rp 64,835
Recommendation
- 1.Safety-critical element: installed on 3 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 409 EA/year: 389 unplanned (recency-weighted compound poisson (own history)) + 20 from the maintenance plan.
- 3.Lead time ~25 days; expected demand during lead time 27.
- 4.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 134, order up to 442.
- 5.Installed on 30 FuncLoc(s), 20 of them criticality A/B.
- 6.ML early warning: 99% probability of demand in the next 90 days.
Safety-critical (SCE)ML early warningLast turnaround used 144Single sourceAbnormal consumptionOpen PO
On hand / on order
156 / 448
next delivery 17 Oct 2026
Today Min / Max
34 / 96
static parameters in BoM
Rec. Min (reorder point)
134
safety stock 108
Rec. Max
442
order qty 308
Service level
99.9%
stockout risk now 0%
Unit price
Rp 64,835
PO history
ML early warning: 99% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 3 issue days in the last 180 days, last issue 63 days ago, 12 failure notifications on its equipment in 90 days, 1 planned jobs in 90 days, 7 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (144 units) excluded from the baseline.
Demand pattern Lumpy · 21 issue days · 1 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 2.5B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~10 days.
Installed on 30 functional locations
20 with criticality A/B · 384 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_BF-107 CRACKING FURNACE BF-107 | A | 4 | 23 | 9.01 |
| PX_HE-1483A C4 PRODUCT COOLER | A | 4 | 11 | 3.22 |
| PX_FCV-621 PP-902B OUTLET FLOW | A | 4 | 4 | 1.39 |
| PX_CL-859 FLUSHING OIL SCRUBBER | A | 16 | 2 | 0.81 |
| PX_KC-663A CONDENSATE FAN | A | 16 | 1 | 0.57 |
| PX_PP-882A CONDENSATE PUMP | A | 4 | 1 | 0.62 |
| PX_FCV-1224 BY PASS LINE | A | 24 | 0 | 0.11 |
| PX_HE-1842D FUEL OIL COOLER | A | 16 | 0 | 0.22 |
| PX_KC-930C SLOP OIL FAN | A | 12 | 0 | 0.57 |
| PX_KT-308B TURBINE FOR KC-308B | A | 16 | 0 | 1.10 |
| PX_PRV-913 SAFETY VALVE HE-1593C | A | 24 | 0 | 0.04 |
| PY_CL-454 C3 RECYCLE TOWER | A | 4 | 0 | 0.38 |
Lead time and procurement
Lead time 25 ± 18 days (PO history, 11 PO lines) · on-time 37%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 24 Aug 2026 | PR03 Regular replenishment | 448 | Rp 64,610 | 17 Oct 2026 open | 54 d |
| 15 Aug 2026 | PR03 Regular replenishment | 267 | Rp 64,377 | 24 Aug 2026 | 9 d |
| 17 Jul 2026 | PR05 Project / turnaround | 203 | Rp 65,646 | 08 Aug 2026 | 22 d |
| 19 May 2026 | PR03 Regular replenishment | 371 | Rp 63,339 | 13 Jun 2026 | 25 d |
| 20 Apr 2026 | PR03 Regular replenishment | 443 | Rp 65,087 | 19 Jun 2026 | 60 d |
| 14 Apr 2026 | PR06 Regular replenishment | 146 | Rp 62,530 | 03 May 2026 | 19 d |
| 06 Apr 2026 | PR05 Project / turnaround | 272 | Rp 62,181 | 16 May 2026 | 40 d |
| 07 Feb 2026 | PR03 Regular replenishment | 220 | Rp 65,043 | 14 Feb 2026 | 7 d |
| 19 Jan 2026 | PR06 Regular replenishment | 244 | Rp 65,857 | 05 Feb 2026 | 17 d |
| 21 Oct 2025 | PR06 Regular replenishment | 447 | Rp 64,835 | 28 Oct 2025 | 7 d |
Planned maintenance demand (next 12 months)
| Due | FuncLoc | Job | Qty |
|---|---|---|---|
| 17 Dec 2026 | PX_FCV-1447 | Final Element Overhaul; CV | 2.86 |
| 01 Feb 2027 | PX_FCV-1932 | Final Element Overhaul; Control Valve | 17.2 |
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 24 Sept 2026 | Low | PX_BF-107 | Install scaffolding at BF-107 |
| 23 Sept 2026 | Medium | PX_HE-1483A | HE-1483A fouling |
| 08 Sept 2026 | Medium | PX_BF-107 | Replace lamp as per PM finding |
| 01 Sept 2026 | Low | PX_KT-447 | Replace lamp as per PM finding |
| 21 Aug 2026 | Low | PX_HE-1483A | Replace lamp as per PM finding |
| 19 Aug 2026 | Medium | PX_FCV-1447 | FCV-1447; IA leak from regulator |
| 15 Aug 2026 | Medium | PX_BF-107 | Hot spot at convection BF-107 |
| 08 Aug 2026 | Low | PX_BF-107 | Cleaning burner BF-107 |
| 21 Jul 2026 | Medium | PX_BF-107 | Replace lamp as per PM finding |
| 21 Jul 2026 | Medium | PX_BF-107 | Thermograph wall BF-107 |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 30 Jul 2026 | 48 | 204000020866 | Preventive |
| 03 Jul 2026 | 96 | 201000000805 | Corrective |
| 31 May 2026 | 24 | 201000020779 | Corrective |
| 24 Mar 2026 | 48 | 201000010975 | Corrective |
| 20 Feb 2026 | 8 | 201000028494 | Corrective |
| 18 Jan 2026 | 8 | 201000011434 | Corrective |
| 04 Jan 2026 | 12 | 201000021786 | Corrective |
| 03 Jan 2026 | 8 | 201000003974 | Corrective |
| 02 Jan 2026 | 32 | 201000037004 | Corrective |
| 17 Dec 2025 | 16 | 201000028633 | Corrective |
| 14 Dec 2025 | 48 | 201000029280 | Corrective |
| 13 Dec 2025 | 24 | 201000007088 | Corrective |
| 12 Dec 2025 | 4 | 204000022083 | Preventive |
| 03 Dec 2025 | 12 | 201000024707 | Corrective |
| 29 Nov 2025 | 8 | 201000008592 | Corrective |