STUDBOLT,3/4INX35MM,B7/2H
Material 4100024990 · STUDBOLT · Plant 1000
ASafety-criticalReorderCriticalInsurance gap
- Material
- 4100024990
- Category
- STUDBOLT
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (6 of 8 FuncLocs A/B, 1 safety/shutdown valve)
- Supplier
- No PO history
- Lead time
- 23 d · P80 39 d
- Unit price
- Rp 37,807 (est.)
Recommendation
- 1.Safety-critical element: installed on 1 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 40 EA/year: 40 unplanned (installed-base failure prior (no history)).
- 3.Lead time ~23 days; expected demand during lead time 2.5.
- 4.A 100.0% service level gives the lowest holding + downtime-risk cost: reorder at 54, order up to 95.
- 5.On hand 0 + on order 0 is at or below the reorder point: order 95 now.
- 6.Installed on 8 FuncLoc(s), 6 of them criticality A/B.
Proposed purchase requisition
95 EA
Rp 3.6M · order by 01 Oct 2026
Expected arrival ≈ 23 days
Safety-critical (SCE)Price estimatedLead time estimated
On hand / on order
0 / 0
no open PO
Today Min / Max
5 / 14
static parameters in BoM
Rec. Min (reorder point)
54
safety stock 52
Rec. Max
95
order qty 41
Service level
100.0%
stockout risk now 9%
Unit price
Rp 37,807
Category + unit estimate
ML early warning: 12% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue never, 24 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern No demand · 0 issue days · method: Installed-base failure prior (no history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 322.2M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~10 days.
Installed on 8 functional locations
6 with criticality A/B · 136 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_BF-106 CRACKING FURNACE BF-106 | A | 24 | 82 | 30.86 |
| PX_KC-317B RICH AMINE FAN | A | 24 | 4 | 1.85 |
| PX_HE-1256A REFLUX PREHEATER | A | 8 | 0 | 0.22 |
| PX_PP-1049 PROPYLENE PUMP | A | 16 | 0 | 0.19 |
| PY_HE-1685D QUENCH OIL CONDENSER | B | 24 | 1 | 0.65 |
| PX_TCV-1288 TEMPERATURE CONTROL VALVE | B | 16 | 0 | 0.12 |
| PX_PP-1872A QUENCH WATER PUMP | S | 12 | 4 | 1.90 |
| PX_PRV-1103B SAFETY VALVE HE-1603 | S | 12 | 2 | 0.90 |
Lead time and procurement
Lead time 23 ± 15 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 29 Sept 2026 | Medium | PX_BF-106 | Decoking follow up BF-106 |
| 29 Sept 2026 | Medium | PX_BF-106 | Decoking follow up BF-106 |
| 28 Sept 2026 | Low | PX_BF-106 | Peep door broken BF-106 |
| 19 Sept 2026 | Medium | PX_BF-106 | Cleaning burner BF-106 |
| 15 Sept 2026 | Medium | PX_BF-106 | Install cover plate BF-106 |
| 14 Sept 2026 | Low | PX_BF-106 | Peep door broken BF-106 |
| 10 Sept 2026 | Medium | PX_BF-106 | Replace burner tip BF-106 |
| 08 Sept 2026 | Low | PX_BF-106 | Leak from packing |
| 08 Sept 2026 | Medium | PX_BF-106 | Painting BF-106 |
| 05 Sept 2026 | Medium | PX_PRV-1103B | Recertification PRV-1103B |
Recent goods issues
Never issued in the 17-month history.