STUDBOLT,7/8INX50MM,B8M/8M
Material 4100026647 · STUDBOLT · Plant 1000
AReorderNormalSlow-moving
- Material
- 4100026647
- Category
- STUDBOLT
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (1 of 5 FuncLocs A/B)
- Supplier
- BINTANG MESINDO PRATAMA PT
- Lead time
- 19 d · P80 39 d
- Unit price
- Rp 10,546
Recommendation
- 1.Forecast 30 EA/year: 27 unplanned (credibility blend: own history + installed-base prior) + 2.9 from the maintenance plan.
- 2.Lead time ~19 days; expected demand during lead time 1.4.
- 3.A 100.0% service level gives the lowest holding + downtime-risk cost: reorder at 32, order up to 62.
- 4.On hand 2 + on order 0 is at or below the reorder point: order 60 now.
- 5.Installed on 5 FuncLoc(s), 1 of them criticality A/B.
Proposed purchase requisition
60 EA
Rp 632,760 · order by 01 Oct 2026
Expected arrival ≈ 19 days
Single source
On hand / on order
2 / 0
no open PO
Today Min / Max
1 / 2
static parameters in BoM
Rec. Min (reorder point)
32
safety stock 31
Rec. Max
62
order qty 30
Service level
100.0%
stockout risk now 9%
Unit price
Rp 10,546
PO history
ML early warning: 18% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue 404 days ago, 1 failure notifications on its equipment in 90 days, 1 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Single issue · 1 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 362.6M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~10 days.
Installed on 5 functional locations
1 with criticality A/B · 48 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_HE-1764C BFW CONDENSER | A | 4 | 2 | 0.65 |
| PX_PCV-1992 BY PASS DUCT | C | 12 | 0 | 0.08 |
| PX_ROF-916 MP STEAM TO VD-708 | C | 12 | 0 | 0.00 |
| PX_KT-264A TURBINE FOR KC-264A | S | 4 | 4 | 2.39 |
| PX_KT-624A TURBINE FOR KC-624A | S | 16 | 3 | 2.39 |
Lead time and procurement
Lead time 19 ± 15 days (PO history + category, 1 PO lines) · on-time 49%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 01 Feb 2026 | PR03 Regular replenishment | 3 | Rp 10,546 | 09 Feb 2026 | 8 d |
Planned maintenance demand (next 12 months)
| Due | FuncLoc | Job | Qty |
|---|---|---|---|
| 26 Dec 2026 | PX_KT-264A | Turbine major overhaul | 2.86 |
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 15 Jul 2026 | Medium | PX_KT-624A | [MSI-B-26-RXR-331/M] Replace line |
| 11 Jun 2026 | Low | PX_KT-264A | Leak from packing |
| 21 Apr 2026 | Low | PX_KT-264A | Follow up after steam upset KT-264A |
| 07 Feb 2026 | Medium | PX_KT-624A | Replace lamp as per PM finding |
| 23 Dec 2025 | Medium | PX_HE-1764C | Cleaning HE-1764C |
| 21 Oct 2025 | Medium | PX_KT-264A | KT-264A governor valve hunting |
| 17 Jun 2025 | Medium | PX_KT-624A | [MSI-B-25-SWV-127/M] Replace line |
| 31 May 2025 | Medium | PX_KT-264A | Install scaffolding at KT-264A |
| 29 May 2025 | Low | PX_HE-1764C | Install scaffolding at HE-1764C |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 23 Aug 2025 | 4 | 201000039859 | Corrective |
| 23 Aug 2025 | 12 | 201000039859 | Corrective |