PIPE,10IN,SCH80,SS316,SMLS,6M LG
Material 4100028481 · PIPE · Plant 1000
AReorderNormalSlow-moving
- Material
- 4100028481
- Category
- PIPE
- Base unit
- LG
- MRP type
- Stock Item
- Criticality
- A (5 of 5 FuncLocs A/B)
- Supplier
- BINTANG MESINDO PRATAMA PT
- Lead time
- 26 d · P80 51 d
- Unit price
- Rp 2.2M
Recommendation
- 1.Forecast 7.7 LG/year: 7.7 unplanned (credibility blend: own history + installed-base prior).
- 2.Lead time ~26 days; expected demand during lead time 0.5.
- 3.A 99.7% service level gives the lowest holding + downtime-risk cost: reorder at 4, order up to 12.
- 4.On hand 2 + on order 0 is at or below the reorder point: order 10 now.
- 5.Installed on 5 FuncLoc(s), 5 of them criticality A/B.
Proposed purchase requisition
10 LG
Rp 21.7M · order by 01 Oct 2026
Expected arrival ≈ 26 days
Single source
On hand / on order
2 / 0
no open PO
Today Min / Max
1 / 2
static parameters in BoM
Rec. Min (reorder point)
4
safety stock 4
Rec. Max
12
order qty 8
Service level
99.7%
stockout risk now 3%
Unit price
Rp 2.2M
PO history
ML early warning: 21% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue 495 days ago, 6 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 1 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Single issue · 1 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 1.1B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~13 days.
Installed on 5 functional locations
5 with criticality A/B · 38 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_BF-109 CRACKING FURNACE BF-109 | A | 2 | 29 | 11.58 |
| PX_HE-149A HYDROGEN COOLER | A | 6 | 2 | 0.65 |
| PX_HE-1817C WASH WATER TLE | A | 6 | 0 | 0.22 |
| PX_20-HS-1722-B21A-T PIPE->16 FROM VD-749A TO HE-236B | B | 12 | 1 | 0.44 |
| PY_HE-965B RECYCLE ETHANE TLE | B | 12 | 0 | 0.22 |
Lead time and procurement
Lead time 26 ± 18 days (PO history + category, 1 PO lines) · on-time 49%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 30 Apr 2026 | PR03 Regular replenishment | 2 | Rp 2.2M | 15 May 2026 | 15 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 20 Sept 2026 | Medium | PX_BF-109 | Thermograph wall BF-109 |
| 13 Sept 2026 | Medium | PX_BF-109 | Install scaffolding at BF-109 |
| 03 Sept 2026 | Low | PX_BF-109 | Install scaffolding at BF-109 |
| 02 Sept 2026 | Low | PX_BF-109 | Install cover plate for MCP cracking |
| 16 Aug 2026 | Medium | PX_BF-109 | Install cover plate BF-109 |
| 13 Jul 2026 | Medium | PX_BF-109 | Cleaning burner BF-109 |
| 09 Jul 2026 | Medium | PX_BF-109 | Thermograph wall BF-109 |
| 09 Jul 2026 | Low | PX_BF-109 | Leak from packing |
| 01 Jul 2026 | Emergency | PX_BF-109 | [MSI-B-26-YDN-280/M] Replace line |
| 23 Jun 2026 | High | PX_BF-109 | Cleaning burner BF-109 |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 24 May 2025 | 2 | 201000007863 | Corrective |