FLANGE,WN,10IN,600#,SS316,RF
Material 4100032857 · FLANGE · Plant 1000
ALong-leadReduceExcess
- Material
- 4100032857
- Category
- FLANGE
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (21 of 57 FuncLocs A/B)
- Supplier
- SAMUDRA SEJAHTERA PERSADA PT
- Lead time
- 84 d · P80 120 d
- Unit price
- Rp 927,596
Recommendation
- 1.Forecast 437 EA/year: 437 unplanned (recency-weighted compound poisson (own history)).
- 2.Lead time ~84 days; expected demand during lead time 101.
- 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 329, order up to 414.
- 4.Stock 465 exceeds the level to keep (414) by 51.
- 5.Long lead time: 80% of deliveries took up to 120 days and the fastest seen in its category 19 days, from a single supplier. Emergency buying cannot prevent downtime: plan ahead or hold as a capital spare.
- 6.Installed on 57 FuncLoc(s), 21 of them criticality A/B.
- 7.ML early warning: 100% probability of demand in the next 90 days.
Long-leadML early warningLast turnaround used 130Single sourceAbnormal consumptionOpen PO
On hand / on order
465 / 2,107
next delivery 15 Oct 2026
Today Min / Max
70 / 189
static parameters in BoM
Rec. Min (reorder point)
329
safety stock 228
Rec. Max
414
order qty 85
Service level
99.9%
stockout risk now 0%
Unit price
Rp 927,596
PO history
ML early warning: 100% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 40 issue days in the last 180 days, last issue 1 days ago, 7 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 18 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (242 units) excluded from the baseline.
Demand pattern Erratic · 152 issue days · 9 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 38.6B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~19 days.
Installed on 57 functional locations
21 with criticality A/B · 72 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_HE-126D DILUTION STEAM PREHEATER | A | 3 | 5 | 1.08 |
| PX_HE-1393C QUENCH WATER PREHEATER | A | 1 | 3 | 1.08 |
| PX_HE-534C SEAL OIL TLE | A | 1 | 3 | 0.65 |
| PX_HE-1455C COOLING WATER COOLER | A | 1 | 1 | 0.22 |
| PX_HE-1256A REFLUX PREHEATER | A | 1 | 0 | 0.22 |
| PX_HE-439C LUBE OIL REBOILER | A | 3 | 0 | 0.22 |
| PX_HE-895B DEMIN WATER EXCHANGER | A | 1 | 0 | 0.22 |
| PX_HE-974 SLOP OIL CONDENSER | A | 1 | 0 | 0.22 |
| PX_ROF-1273A MP STEAM TO VD-1479 | A | 1 | 0 | 0.00 |
| PY_HE-724 ETHYLENE REBOILER | A | 1 | 0 | 0.22 |
| PX_HE-1874C METHANOL COOLER | B | 1 | 3 | 1.08 |
| PX_HE-1164D QUENCH WATER CONDENSER | B | 1 | 2 | 1.08 |
Lead time and procurement
Lead time 84 ± 57 days (PO history, 57 PO lines) · on-time 42%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 07 Sept 2026 | PR05 Project / turnaround | 322 | Rp 939,077 | 19 Feb 2027 open | 165 d |
| 05 Sept 2026 | PR05 Project / turnaround | 177 | Rp 926,631 | 27 Jan 2027 open | 144 d |
| 22 Aug 2026 | PR03 Regular replenishment | 224 | Rp 911,126 | 09 Nov 2026 open | 79 d |
| 19 Aug 2026 | PR04 Regular (other) | 197 | Rp 899,970 | 25 Nov 2026 open | 98 d |
| 17 Aug 2026 | PR03 Regular replenishment | 151 | Rp 930,646 | 19 May 2027 open | 275 d |
| 11 Aug 2026 | PR06 Regular replenishment | 336 | Rp 889,926 | 05 Sept 2026 | 25 d |
| 04 Aug 2026 | PR06 Regular replenishment | 253 | Rp 924,328 | 22 Sept 2026 | 49 d |
| 01 Aug 2026 | PR03 Regular replenishment | 181 | Rp 946,262 | 09 Sept 2026 | 39 d |
| 30 Jul 2026 | PR03 Regular replenishment | 459 | Rp 904,440 | 15 Oct 2026 open | 77 d |
| 27 Jul 2026 | PR03 Regular replenishment | 392 | Rp 892,319 | 03 Nov 2026 open | 99 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 29 Aug 2026 | Low | PX_HE-126D | Replace lamp as per PM finding |
| 26 Aug 2026 | Medium | PX_HE-1393C | HE-1393C tube leak |
| 24 Aug 2026 | Medium | PX_3/4-FG-20458-A41A-HS | Replace lamp as per PM finding |
| 23 Aug 2026 | High | PX_HE-1393C | Replace lamp as per PM finding |
| 22 Aug 2026 | Medium | PX_1-BF-24318-A22A-HS | Clean dummy leg 1-BF-24318-A22A-HS |
| 08 Jul 2026 | Medium | PX_HE-1874C | Replace lamp as per PM finding |
| 06 Jul 2026 | Medium | PX_HE-126D | Install scaffolding at HE-126D |
| 04 Jul 2026 | Medium | PX_HE-1164D | Leak from packing |
| 13 May 2026 | Medium | PX_HE-1727 | HE-1727 fouling |
| 03 Mar 2026 | Medium | PX_HE-1874C | Leak from packing |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 30 Sept 2026 | 3 | 201000031410 | Corrective |
| 27 Sept 2026 | 3 | 201000014873 | Corrective |
| 22 Sept 2026 | 1 | 201000013988 | Corrective |
| 21 Sept 2026 | 1 | 201000010227 | Corrective |
| 18 Sept 2026 | 2 | 209000036917 | Other maintenance |
| 10 Sept 2026 | 6 | 201000035065 | Corrective |
| 10 Sept 2026 | 1 | 204000002121 | Preventive |
| 06 Sept 2026 | 3 | 201000022798 | Corrective |
| 04 Sept 2026 | 1 | 201000031484 | Corrective |
| 23 Aug 2026 | 2 | 201000000994 | Corrective |
| 22 Aug 2026 | 2 | 201000010149 | Corrective |
| 14 Aug 2026 | 10 | 209000023087 | Other maintenance |
| 12 Aug 2026 | 1 | 201000033551 | Corrective |
| 10 Aug 2026 | 2 | 201000035120 | Corrective |
| 31 Jul 2026 | 8 | 201000033262 | Corrective |