CONNECTOR,MALE,1/2IN ODT,1/2IN NPT,SS316
Material 4100039984 · CONNECTOR · Plant 1000
AReduceExcess
- Material
- 4100039984
- Category
- CONNECTOR
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (15 of 60 FuncLocs A/B)
- Supplier
- KARYA ENERGI SENTOSA PT
- Lead time
- 28 d · P80 37 d
- Unit price
- Rp 291,686
Recommendation
- 1.Forecast 14 EA/year: 14 unplanned (recency-weighted compound poisson (own history)).
- 2.Lead time ~28 days; expected demand during lead time 1.1.
- 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 6, order up to 20.
- 4.Stock 22 exceeds the level to keep (20) by 2.
- 5.Installed on 60 FuncLoc(s), 15 of them criticality A/B.
- 6.ML early warning: 64% probability of demand in the next 90 days.
ML early warningSingle sourceAbnormal consumptionSame description as 19 other material numbers
On hand / on order
22 / 0
no open PO
Today Min / Max
13 / 36
static parameters in BoM
Rec. Min (reorder point)
6
safety stock 5
Rec. Max
20
order qty 14
Service level
99.9%
stockout risk now 0%
Unit price
Rp 291,686
PO history
ML early warning: 64% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 2 issue days in the last 180 days, last issue 101 days ago, 3 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 4 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Lumpy · 19 issue days · 1 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 2.7B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~14 days.
Installed on 60 functional locations
15 with criticality A/B · 74 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_FIT-996 SLOP OIL FLOW | A | 1 | 2 | 0.04 |
| PX_TIT-1612 TEMPERATURE | A | 1 | 1 | 0.04 |
| PX_LIT-657 LEVEL | A | 1 | 0 | 0.03 |
| PX_TEL-1676 KC-618B BTM | A | 1 | 0 | 0.01 |
| PY_LIT-1742A-50A PP-448 LEVEL | A | 1 | 0 | 0.03 |
| PX_FIT-1115 HE-605 INLET FLOW | B | 1 | 2 | 0.47 |
| PX_FIT-1494A FLUSHING OIL FLOW | B | 1 | 0 | 0.04 |
| PX_FIT-1738 DILUTION STEAM FLOW | B | 1 | 0 | 0.04 |
| PX_FIT-229B PP-790A INLET FLOW | B | 1 | 0 | 0.04 |
| PX_PGI-683 VD-422 SUCTION | B | 1 | 0 | 0.02 |
| PX_PIT-1324 PRESSURE | B | 1 | 0 | 0.04 |
| PX_TEL-1540 TEMPERATURE | B | 1 | 0 | 0.01 |
Lead time and procurement
Lead time 28 ± 12 days (PO history, 12 PO lines) · on-time 38%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 28 Aug 2026 | PR03 Regular replenishment | 14 | Rp 283,642 | 28 Sept 2026 | 31 d |
| 13 Aug 2026 | PR03 Regular replenishment | 13 | Rp 273,005 | 08 Sept 2026 | 26 d |
| 25 May 2026 | PR03 Regular replenishment | 10 | Rp 293,879 | 23 Jun 2026 | 29 d |
| 10 Apr 2026 | PR03 Regular replenishment | 9 | Rp 296,101 | 20 May 2026 | 40 d |
| 30 Mar 2026 | PR03 Regular replenishment | 10 | Rp 279,716 | 24 Apr 2026 | 25 d |
| 17 Jan 2026 | PR03 Regular replenishment | 13 | Rp 291,958 | 07 Feb 2026 | 21 d |
| 04 Jan 2026 | PR06 Regular replenishment | 13 | Rp 293,702 | 18 Jan 2026 | 14 d |
| 09 Nov 2025 | PR06 Regular replenishment | 13 | Rp 292,302 | 25 Dec 2025 | 46 d |
| 30 Aug 2025 | PR03 Regular replenishment | 15 | Rp 296,349 | 15 Sept 2025 | 16 d |
| 05 Aug 2025 | PR03 Regular replenishment | 12 | Rp 291,414 | 12 Sept 2025 | 38 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 17 Sept 2026 | Medium | PX_PGI-147 | Replace PGI-147 |
| 22 Aug 2026 | Low | PX_FIT-1115 | FIT-1115 error |
| 02 Aug 2026 | Low | PX_TEL-1939 | Replace lamp as per PM finding |
| 06 Mar 2026 | Emergency | PX_PGI-147 | Repair insulation PGI-147 |
| 26 Dec 2025 | Medium | PX_TEL-1049C | Leak from packing |
| 04 Dec 2025 | Medium | PX_FIT-996 | Install scaffolding at FIT-996 |
| 05 Nov 2025 | Low | PX_LIT-166 | Install scaffolding at LIT-166 |
| 03 Oct 2025 | Emergency | PX_PGI-147 | [MSI-B-25-GSG-347/M] Replace line |
| 16 Jul 2025 | Low | PX_PGI-147 | Replace lamp as per PM finding |
| 15 Jul 2025 | Medium | PX_TIT-1612 | Install scaffolding at TIT-1612 |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 22 Jun 2026 | 1 | 201000013071 | Corrective |
| 16 Jun 2026 | 1 | 201000014984 | Corrective |
| 22 Jan 2026 | 1 | 201000035361 | Corrective |
| 21 Jan 2026 | 1 | 201000035361 | Corrective |
| 16 Jan 2026 | 1 | 201000025571 | Corrective |
| 03 Jan 2026 | 1 | 201000021786 | Corrective |
| 24 Dec 2025 | 3 | 201000018957 | Corrective |
| 20 Dec 2025 | 1 | 201000028627 | Corrective |
| 20 Dec 2025 | 1 | 201000033402 | Corrective |
| 11 Dec 2025 | 1 | 201000026601 | Corrective |
| 10 Dec 2025 | 2 | 201000019124 | Corrective |
| 05 Dec 2025 | 5 | 201000006166 | Corrective |
| 04 Dec 2025 | 1 | 201000026242 | Corrective |
| 28 Sept 2025 | 3 | 201000035635 | Corrective |
| 27 Sept 2025 | 1 | 201000035635 | Corrective |