TRIM SET,CONTROL VALVE,MODEL RD612,INCOL
Material 4100043347 · TRIM SET · Plant 1000
AReduceExcess
- Material
- 4100043347
- Category
- TRIM SET
- Base unit
- SET
- MRP type
- Non Stock
- Criticality
- A (19 of 32 FuncLocs A/B)
- Supplier
- No PO history
- Lead time
- 159 d · P80 236 d
- Unit price
- Rp 78.5M (est.)
Recommendation
- 1.Forecast 2.8 SET/year: 2.8 unplanned (credibility blend: own history + installed-base prior).
- 2.Lead time ~159 days; expected demand during lead time 1.2.
- 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 5, order up to 6.
- 4.Stock 31 exceeds the level to keep (6) by 25.
- 5.Installed on 32 FuncLoc(s), 19 of them criticality A/B.
Price estimatedLead time estimated
On hand / on order
31 / 0
no open PO
Today Min / Max
0 / 0
static parameters in BoM
Rec. Min (reorder point)
5
safety stock 4
Rec. Max
6
order qty 1
Service level
99.9%
stockout risk now 0%
Unit price
Rp 78.5M
Category + unit estimate
ML early warning: 21% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 2 issue days in the last 180 days, last issue 118 days ago, 2 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Single issue · 2 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 4.4B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~75 days.
Installed on 32 functional locations
19 with criticality A/B · 45 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_PCV-143A HE-1596B PRESSURE CONTROL | A | 1 | 1 | 0.08 |
| PX_TCV-1344 TEMPERATURE CONTROL VALVE | A | 1 | 1 | 0.12 |
| PY_TCV-1902 HE-1026 TEMP CONTROL | A | 1 | 1 | 0.12 |
| PX_FCV-1152 RECYCLE ETHANE FLOW CONTROL | A | 1 | 0 | 0.11 |
| PX_FCV-1181 CONTROL VALVE | A | 1 | 0 | 0.11 |
| PX_LCV-1400 HE-1767 LEVEL CONTROL | A | 4 | 0 | 0.12 |
| PX_LCV-619A LEVEL CONTROL VALVE | A | 4 | 0 | 0.12 |
| PX_PCV-1407 PP-1125B PRESSURE CONTROL | A | 3 | 0 | 0.08 |
| PX_PCV-380 HE-1557D PRESSURE CONTROL | A | 1 | 0 | 0.08 |
| PX_PCV-809 PP-167 PRESSURE CONTROL | A | 1 | 0 | 0.08 |
| PX_PCV-984 KC-984C PRESSURE CONTROL | A | 2 | 0 | 0.08 |
| PX_LCV-1372A PP-1720D LEVEL CONTROL | B | 1 | 4 | 1.83 |
Lead time and procurement
Lead time 159 ± 83 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 25 Jul 2026 | Medium | PX_LCV-1372A | [MSI-B-26-YDT-175/M] Replace line |
| 05 Jul 2026 | Medium | PX_LCV-365 | LCV-365; valve hunting |
| 07 Jun 2026 | Medium | PX_TCV-240 | Replace lamp as per PM finding |
| 29 Mar 2026 | Medium | PX_LCV-1372A | Overhaul LCV-1372A |
| 18 Jan 2026 | Medium | PX_TCV-240 | TCV-240; small leak at packing |
| 30 Dec 2025 | Low | PX_LCV-1372A | Replace lamp as per PM finding |
| 12 Dec 2025 | Low | PX_PCV-1713 | PCV-1713; small leak at packing |
| 03 Nov 2025 | Medium | PX_PCV-1713 | PCV-1713 passing |
| 28 Oct 2025 | Medium | PX_PCV-1713 | Overhaul PCV-1713 |
| 23 Sept 2025 | Medium | PX_TCV-240 | TCV-240 passing |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 05 Jun 2026 | 1 | 201000009741 | Corrective |
| 04 Jun 2026 | 1 | 201000009741 | Corrective |