TRIM SET,CONTROL VALVE,MODEL GP627,SS316
Material 4100043407 · TRIM SET · Plant 1000
AReorderCriticalStockout
- Material
- 4100043407
- Category
- TRIM SET
- Base unit
- SET
- MRP type
- Stock Item
- Criticality
- A (9 of 16 FuncLocs A/B)
- Supplier
- No PO history
- Lead time
- 159 d · P80 236 d
- Unit price
- Rp 78.5M (est.)
Recommendation
- 1.Forecast 3.2 SET/year: 3.2 unplanned (credibility blend: own history + installed-base prior).
- 2.Lead time ~159 days; expected demand during lead time 1.4.
- 3.A 99.7% service level gives the lowest holding + downtime-risk cost: reorder at 6, order up to 8.
- 4.On hand 0 + on order 0 is at or below the reorder point: order 8 now.
- 5.Installed on 16 FuncLoc(s), 9 of them criticality A/B.
Proposed purchase requisition
8 SET
Rp 627.9M · order by 01 Oct 2026
Expected arrival ≈ 159 days
Price estimatedLead time estimated
On hand / on order
0 / 0
no open PO
Today Min / Max
1 / 2
static parameters in BoM
Rec. Min (reorder point)
6
safety stock 5
Rec. Max
8
order qty 2
Service level
99.7%
stockout risk now 61%
Unit price
Rp 78.5M
Category + unit estimate
ML early warning: 22% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 1 issue days in the last 180 days, last issue 62 days ago, 0 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Intermittent · 4 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 3.4B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~75 days.
Installed on 16 functional locations
9 with criticality A/B · 22 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_FCV-610B PP-251C OUTLET FLOW | A | 1 | 2 | 0.11 |
| PX_TCV-868 TEMPERATURE CONTROL VALVE | A | 1 | 2 | 0.55 |
| PX_TCV-880 TEMPERATURE CONTROL VALVE | A | 1 | 1 | 0.12 |
| PX_FCV-933A RECYCLE ETHANE FLOW CONTROL | A | 1 | 0 | 0.11 |
| PX_LCV-1703 PP-1325 LEVEL CONTROL | A | 1 | 0 | 0.12 |
| PX_PCV-194 HE-1680D PRESSURE CONTROL | A | 4 | 0 | 0.08 |
| PX_LCV-482 CL-899 LEVEL CONTROL | B | 1 | 1 | 0.12 |
| PX_PCV-1940 VD-928B PRESSURE CONTROL | B | 1 | 0 | 0.08 |
| PX_TCV-529 TEMPERATURE CONTROL VALVE | B | 1 | 0 | 0.12 |
| PX_FCV-1570B BY PASS LINE | C | 1 | 1 | 0.11 |
| PX_FCV-550 RICH AMINE FLOW CONTROL | C | 1 | 0 | 0.11 |
| PX_PCV-367 VD-450 PRESSURE CONTROL | C | 1 | 0 | 0.08 |
Lead time and procurement
Lead time 159 ± 83 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 25 Dec 2025 | Medium | PX_TCV-868 | [MSI-B-25-TDD-370] Permanent repair |
| 10 Sept 2025 | Low | PX_FCV-610B | Install scaffolding at FCV-610B |
| 17 Jul 2025 | Medium | PX_FCV-1570B | PSM25/Install scaffolding at FCV-1570B |
| 27 May 2025 | Medium | PX_TCV-880 | Install scaffolding at TCV-880 |
| 26 May 2025 | High | PX_LCV-482 | Leak from packing |
| 23 May 2025 | Low | PX_FCV-610B | Replace lamp as per PM finding |
| 17 May 2025 | Low | PX_FCV-1289 | Leak from packing |
| 11 May 2025 | High | PX_TCV-868 | PSM25/TCV-868; IA leak from regulator |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 31 Jul 2026 | 2 | 201000001731 | Corrective |
| 16 Dec 2025 | 1 | 201000020854 | Corrective |
| 14 Dec 2025 | 2 | 201000025743 | Corrective |
| 23 Oct 2025 | 1 | 201000029226 | Corrective |