PACKING SET,VALVE,TYPE GE526,NBR
Material 4100045462 · PACKING SET · Plant 1000
ASafety-criticalLong-leadReduceSlow-moving
- Material
- 4100045462
- Category
- PACKING SET
- Base unit
- SET
- MRP type
- Stock Item
- Criticality
- A (2 of 8 FuncLocs A/B, 2 safety/shutdown valve)
- Supplier
- SAMUDRA UTAMA GLOBAL PT
- Lead time
- 120 d · P80 145 d
- Unit price
- Rp 1.9M
Recommendation
- 1.Safety-critical element: installed on 2 safety or shutdown valve location(s). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 1.1 SET/year: 1.1 unplanned (credibility blend: own history + installed-base prior).
- 3.Lead time ~120 days; expected demand during lead time 0.4.
- 4.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 3, order up to 5.
- 5.Stock 49 exceeds the level to keep (5) by 44.
- 6.Long lead time: 80% of deliveries took up to 145 days and the fastest seen in its category 38 days, from a single supplier. Emergency buying cannot prevent downtime: plan ahead or hold as a capital spare.
- 7.Installed on 8 FuncLoc(s), 2 of them criticality A/B.
Safety-critical (SCE)Long-leadLast turnaround used 2Single source
On hand / on order
49 / 0
no open PO
Today Min / Max
1 / 2
static parameters in BoM
Rec. Min (reorder point)
3
safety stock 3
Rec. Max
5
order qty 2
Service level
99.9%
stockout risk now 0%
Unit price
Rp 1.9M
PO history
ML early warning: 9% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue 226 days ago, 3 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (2 units) excluded from the baseline.
Demand pattern Intermittent · 2 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 940.2M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~38 days.
Installed on 8 functional locations
2 with criticality A/B · 8 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_PCV-1011A PRESSURE CONTROL VALVE | A | 1 | 0 | 0.08 |
| PX_SDV-1313 ON-OFF VALVE | A | 1 | 0 | 0.06 |
| PX_LCV-1651B LEVEL CONTROL VALVE | C | 1 | 4 | 1.83 |
| PX_FCV-870 PP-1748 OUTLET FLOW | C | 1 | 2 | 0.54 |
| PX_TCV-523A TEMPERATURE CONTROL VALVE | C | 1 | 1 | 0.12 |
| PX_FCV-1761A VD-1044 OUTLET FLOW | C | 1 | 0 | 0.11 |
| PX_PCV-812C PP-1934A PRESSURE CONTROL | C | 1 | 0 | 0.08 |
| PX_SDV-190 PP-1805A SHUTDOWN VALVE | S | 1 | 0 | 0.06 |
Lead time and procurement
Lead time 120 ± 50 days (PO history + category, 2 PO lines) · on-time 47%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 02 Nov 2025 | PR03 Regular replenishment | 2 | Rp 1.9M | 13 Apr 2026 | 162 d |
| 20 Sept 2025 | PR03 Regular replenishment | 1 | Rp 2.0M | 14 Mar 2026 | 175 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 10 Sept 2026 | Low | PX_LCV-1651B | Install cover plate for MCP cracking |
| 11 Aug 2026 | Medium | PX_FCV-870 | [MSI-B-26-FHG-172/M] Replace line |
| 23 Jul 2026 | Low | PX_LCV-1651B | LCV-1651B; IA leak from regulator |
| 22 Apr 2026 | Low | PX_LCV-1651B | LCV-1651B; IA leak from regulator |
| 12 Jun 2025 | Medium | PX_LCV-1651B | LCV-1651B stuck |
| 30 May 2025 | Medium | PX_FCV-870 | FCV-870 passing |
| 22 May 2025 | Medium | PX_TCV-523A | Replace lamp as per PM finding |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 17 Feb 2026 | 1 | 201000002211 | Corrective |
| 12 Nov 2025 | 1 | 203000023445 | Turnaround |
| 10 Nov 2025 | 1 | 203000023445 | Turnaround |
| 19 Sept 2025 | 1 | 201000038882 | Corrective |