DIAPHRAGM,ACTUATOR,SIZE NV280,MONEL
Material 4100046921 · DIAPHRAGM · Plant 1000
AReduceNon-moving
- Material
- 4100046921
- Category
- DIAPHRAGM
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (5 of 7 FuncLocs A/B)
- Supplier
- No PO history
- Lead time
- 134 d · P80 191 d
- Unit price
- Rp 4.4M (est.)
Recommendation
- 1.Forecast 0.8 EA/year: 0.1 unplanned (installed-base failure prior (no history)) + 0.7 from the maintenance plan.
- 2.Lead time ~134 days; expected demand during lead time 0.8 (incl. 0.7 planned).
- 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 2, order up to 3.
- 4.Stock 431 exceeds the level to keep (3) by 428.
- 5.Installed on 7 FuncLoc(s), 5 of them criticality A/B.
Planned demand in lead timePrice estimatedLead time estimated
On hand / on order
431 / 0
no open PO
Today Min / Max
10 / 20
static parameters in BoM
Rec. Min (reorder point)
2
safety stock 2
Rec. Max
3
order qty 1
Service level
99.9%
stockout risk now 0%
Unit price
Rp 4.4M
Category + unit estimate
ML early warning: 19% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue never, 1 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern No demand · 0 issue days · method: Installed-base failure prior (no history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 98.8M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~46 days.
Installed on 7 functional locations
5 with criticality A/B · 7 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_FCV-1152 RECYCLE ETHANE FLOW CONTROL | A | 1 | 0 | 0.11 |
| PX_FCV-1863 BY PASS LINE | A | 1 | 0 | 0.11 |
| PX_TCV-147 KC-717 TEMP CONTROL | A | 1 | 0 | 0.12 |
| PX_FCV-303 BY PASS LINE | B | 1 | 2 | 0.96 |
| PX_PCV-1940 VD-928B PRESSURE CONTROL | B | 1 | 0 | 0.08 |
| PY_LCV-1154A VD-1129 LEVEL CONTROL | C | 1 | 3 | 0.97 |
| PX_FCV-1932 BY PASS LINE | C | 1 | 0 | 0.11 |
Lead time and procurement
Lead time 134 ± 82 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
| Due | FuncLoc | Job | Qty |
|---|---|---|---|
| 01 Feb 2027 | PX_FCV-1932 | Final Element Overhaul; Control Valve | 0.72 |
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 21 Aug 2026 | Medium | PX_FCV-303 | Leak from packing |
| 05 Nov 2025 | Medium | PY_LCV-1154A | LCV-1154A passing |
| 23 Aug 2025 | Low | PY_LCV-1154A | LCV-1154A; valve hunting |
| 13 Jul 2025 | Medium | PX_FCV-303 | Leak from packing |
| 17 May 2025 | Medium | PY_LCV-1154A | Overhaul LCV-1154A |
Recent goods issues
Never issued in the 17-month history.