SEAT RING,VALVE,SIZE MG172,SS304
Material 4100050234 · SEAT RING · Plant 1000
AReorderCriticalStockout
- Material
- 4100050234
- Category
- SEAT RING
- Base unit
- EA
- MRP type
- Non Stock
- Criticality
- A (5 of 9 FuncLocs A/B)
- Supplier
- KARYA ENERGI SENTOSA PT
- Lead time
- 91 d · P80 86 d
- Unit price
- Rp 8.0M
Recommendation
- 1.Forecast 1.7 EA/year: 1.7 unplanned (credibility blend: own history + installed-base prior).
- 2.Lead time ~91 days; expected demand during lead time 0.4.
- 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 3, order up to 5.
- 4.On hand 0 + on order 0 is at or below the reorder point: order 5 now.
- 5.Installed on 9 FuncLoc(s), 5 of them criticality A/B.
Proposed purchase requisition
5 EA
Rp 39.9M · order by 01 Oct 2026
Expected arrival ≈ 91 days
Convert to Stock ItemSingle source
On hand / on order
0 / 0
no open PO
Today Min / Max
0 / 0
static parameters in BoM
Rec. Min (reorder point)
3
safety stock 3
Rec. Max
5
order qty 2
Service level
99.9%
stockout risk now 34%
Unit price
Rp 8.0M
PO history
ML early warning: 23% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 2 issue days in the last 180 days, last issue 138 days ago, 1 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Intermittent · 3 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 2.4B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~65 days.
Installed on 9 functional locations
5 with criticality A/B · 9 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_TCV-1322 PP-743D TEMP CONTROL | A | 1 | 1 | 0.12 |
| PX_TCV-1654A KC-513 TEMP CONTROL | A | 1 | 0 | 0.12 |
| PX_TCV-293 TEMPERATURE CONTROL VALVE | A | 1 | 0 | 0.12 |
| PX_PCV-1691B BY PASS DUCT | B | 1 | 4 | 0.94 |
| PY_LCV-191C LEVEL CONTROL VALVE | B | 1 | 1 | 0.12 |
| PX_TCV-1659A VD-756B TEMP CONTROL | S | 1 | 1 | 0.12 |
| PX_LCV-1822 KC-840A LEVEL CONTROL | S | 1 | 0 | 0.12 |
| PX_PCV-945 HE-118B PRESSURE CONTROL | S | 1 | 0 | 0.08 |
| PX_TCV-562 HE-643D TEMP CONTROL | S | 1 | 0 | 0.12 |
Lead time and procurement
Lead time 91 ± 42 days (PO history, 3 PO lines) · on-time 38%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 14 Mar 2026 | PR06 Regular replenishment | 1 | Rp 7.9M | 06 Jun 2026 | 84 d |
| 16 Dec 2025 | PR06 Regular replenishment | 2 | Rp 8.3M | 27 Jan 2026 | 42 d |
| 10 May 2025 | PR06 Regular replenishment | 1 | Rp 8.0M | 06 Aug 2025 | 88 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 08 Sept 2026 | Medium | PX_PCV-1691B | Install scaffolding at PCV-1691B |
| 09 Jul 2026 | Medium | PX_PCV-1691B | PCV-1691B; IA leak from regulator |
| 04 Mar 2026 | Low | PX_PCV-1691B | Install scaffolding at PCV-1691B |
| 08 Jul 2025 | Medium | PX_PCV-1691B | PCV-1691B; small leak at packing |
| 12 May 2025 | Medium | PX_TCV-1659A | PSM25/TCV-1659A; IA leak from regulator |
| 10 May 2025 | Medium | PX_TCV-1322 | Overhaul TCV-1322 |
| 03 May 2025 | Medium | PY_LCV-191C | PSM25/Leak from packing |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 16 May 2026 | 1 | 201000011261 | Corrective |
| 13 May 2026 | 1 | 205000017276 | Other maintenance |
| 27 Sept 2025 | 1 | 201000015747 | Corrective |