GAUGE,PRESSURE,0-10KG/CM2,4IN DIAL
Material 4100064328 · GAUGE · Plant 1000
AReduceSlow-moving
- Material
- 4100064328
- Category
- GAUGE
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (6 of 15 FuncLocs A/B)
- Supplier
- PRIMA SUPLINDO JAYA PT
- Lead time
- 52 d · P80 89 d
- Unit price
- Rp 907,440
Recommendation
- 1.Forecast 4.0 EA/year: 4.0 unplanned (recency-weighted compound poisson (own history)).
- 2.Lead time ~52 days; expected demand during lead time 0.6.
- 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 5, order up to 10.
- 4.Stock 51 exceeds the level to keep (10) by 41.
- 5.Installed on 15 FuncLoc(s), 6 of them criticality A/B.
- 6.ML early warning: 58% probability of demand in the next 90 days.
ML early warningSingle sourceAbnormal consumptionSame description as 5 other material numbers
On hand / on order
51 / 0
no open PO
Today Min / Max
1 / 3
static parameters in BoM
Rec. Min (reorder point)
5
safety stock 5
Rec. Max
10
order qty 5
Service level
99.9%
stockout risk now 0%
Unit price
Rp 907,440
PO history
ML early warning: 58% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue 252 days ago, 1 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 1 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Intermittent · 7 issue days · 1 abnormal issue(s) capped · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 846.0M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~15 days.
Installed on 15 functional locations
6 with criticality A/B · 17 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_PGI-1610 PRESSURE GAUGE | A | 1 | 0 | 0.02 |
| PX_PGI-1304C PP-1309C SUCTION | B | 1 | 1 | 0.44 |
| PX_PGI-1703 PRESSURE GAUGE | B | 1 | 0 | 0.02 |
| PX_PGI-1924D-39B PP-596A SUCTION | B | 1 | 0 | 0.02 |
| PX_PGI-1932 PRESSURE GAUGE | B | 1 | 0 | 0.02 |
| PY_PGI-1988A PP-807B BTM | B | 1 | 0 | 0.02 |
| PX_PGI-147 KC-830D BTM | C | 1 | 4 | 1.73 |
| PX_PGI-1168C PRESSURE GAUGE | C | 1 | 0 | 0.02 |
| PX_PGI-1283-59 PP-1168D BTM | C | 1 | 0 | 0.02 |
| PX_PGI-1570-37A PRESSURE GAUGE | C | 1 | 0 | 0.02 |
| PX_PGI-1795 PRESSURE GAUGE | C | 3 | 0 | 0.02 |
| PX_PGI-331 PP-1352 DISCHARGE | C | 1 | 0 | 0.02 |
Lead time and procurement
Lead time 52 ± 27 days (PO history, 4 PO lines) · on-time 32%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 15 Jun 2026 | PR06 Regular replenishment | 4 | Rp 902,495 | 26 Sept 2026 | 103 d |
| 16 Oct 2025 | PR06 Regular replenishment | 6 | Rp 912,384 | 28 Nov 2025 | 43 d |
| 10 Oct 2025 | PR03 Regular replenishment | 7 | Rp 916,798 | 20 Nov 2025 | 41 d |
| 25 Jun 2025 | PR03 Regular replenishment | 3 | Rp 866,616 | 12 Sept 2025 | 79 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 17 Sept 2026 | Medium | PX_PGI-147 | Replace PGI-147 |
| 06 Mar 2026 | Emergency | PX_PGI-147 | Repair insulation PGI-147 |
| 03 Oct 2025 | Emergency | PX_PGI-147 | [MSI-B-25-GSG-347/M] Replace line |
| 24 Jul 2025 | Medium | PX_PGI-1304C | Replace PGI-1304C |
| 16 Jul 2025 | Low | PX_PGI-147 | Replace lamp as per PM finding |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 22 Jan 2026 | 1 | 201000029233 | Corrective |
| 28 Dec 2025 | 1 | 201000031912 | Corrective |
| 27 Dec 2025 | 1 | 201000031912 | Corrective |
| 19 Aug 2025 | 1 | 201000028209 | Corrective |
| 19 Aug 2025 | 2 | 201000029070 | Corrective |
| 28 Jul 2025 | 4 | 201000016113 | Corrective |
| 27 Jul 2025 | 1 | 201000016113 | Corrective |
| 26 Jul 2025 | 1 | 201000016113 | Corrective |