Sparely
DU

CASTABLE,REFRACTORY,INSUL,1600DEG C

Material 4100073733 · CASTABLE · Plant 1000

AReduceSlow-moving
Material
4100073733
Category
CASTABLE
Base unit
KG
MRP type
Stock Item
Criticality
A (1 of 2 FuncLocs A/B)
Supplier
No PO history
Lead time
58 d · P80 92 d
Unit price
Rp 43,840 (est.)

Recommendation

  • 1.Forecast 212 KG/year: 212 unplanned (installed-base failure prior (no history)).
  • 2.Lead time ~58 days; expected demand during lead time 34.
  • 3.A 99.9% service level gives the lowest holding + downtime-risk cost: reorder at 272, order up to 485.
  • 4.Stock 1,483 exceeds the level to keep (485) by 998.
  • 5.Installed on 2 FuncLoc(s), 1 of them criticality A/B.
Price estimatedLead time estimatedSame description as 3 other material numbers
On hand / on order
1,483 / 0
no open PO
Today Min / Max
661 / 1,101
static parameters in BoM
Rec. Min (reorder point)
272
safety stock 239
Rec. Max
485
order qty 213
Service level
99.9%
stockout risk now 0%
Unit price
Rp 43,840
Category + unit estimate
ML early warning: 2% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue never, 31 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.

Consumption history and 12-month forecast

Units per month. Turnaround issues (1,000 units) excluded from the baseline.

Demand pattern No demand · 0 issue days · method: Installed-base failure prior (no history).

Cost of each service level

Annual holding vs downtime-risk cost for this part

Not stocking at all would cost Rp 1.5B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~30 days.

Installed on 2 functional locations

1 with criticality A/B · 3,025 units installed

FuncLocCrit.InstalledNotificationsFailures / yr
PX_BF-105
CRACKING FURNACE BF-105
A3,00011442.86
PX_BF-110
CRACKING FURNACE BF-110
S254114.58

Lead time and procurement

Lead time 58 ± 27 days (Category estimate, 0 PO lines) · on-time –

No purchase history: price and lead time are estimated from parts of the same category.

Planned maintenance demand (next 12 months)

No part-consuming maintenance job uses this part in the next 12 months.

Recent notifications on its equipment

DatePriorityFuncLocDescription
29 Sept 2026HighPX_BF-105Repair refractory crack BF-105
21 Sept 2026MediumPX_BF-110Replace burner tip BF-110
20 Sept 2026MediumPX_BF-105Replace lamp as per PM finding
20 Sept 2026MediumPX_BF-105Install scaffolding at BF-105
17 Sept 2026MediumPX_BF-110Install scaffolding at BF-110
15 Sept 2026MediumPX_BF-110Decoking follow up BF-110
14 Sept 2026LowPX_BF-105Install cover plate BF-105
13 Sept 2026MediumPX_BF-105Thermograph wall BF-105
11 Sept 2026MediumPX_BF-110Leak from packing
06 Sept 2026MediumPX_BF-105Repair insulation BF-105

Recent goods issues

Posting dateQtyOrderOrder type
25 Jun 20251,000203000034428Turnaround