CASTABLE,REFRACTORY,INSUL,1700DEG C
Material 4100075042 · CASTABLE · Plant 1000
SMonitorPotentially obsolete
- Material
- 4100075042
- Category
- CASTABLE
- Base unit
- KG
- MRP type
- Stock Item
- Criticality
- S (0 of 1 FuncLocs A/B)
- Supplier
- No PO history
- Lead time
- 58 d · P80 92 d
- Unit price
- Rp 43,840 (est.)
Recommendation
- 1.Forecast 54 KG/year: 54 unplanned (installed-base failure prior (no history)).
- 2.Lead time ~58 days; expected demand during lead time 8.6.
- 3.A 91.0% service level gives the lowest holding + downtime-risk cost: reorder at 0, order up to 91.
Price estimatedLead time estimatedSame description as 2 other material numbers
On hand / on order
5 / 0
no open PO
Today Min / Max
2 / 6
static parameters in BoM
Rec. Min (reorder point)
0
safety stock 0
Rec. Max
91
order qty 91
Service level
91.0%
stockout risk now 9%
Unit price
Rp 43,840
Category + unit estimate
ML early warning: 1% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue never, 10 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern No demand · 0 issue days · method: Installed-base failure prior (no history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 1.4M/yr in expected downtime and emergency buys. A stockout here stops production with probability 0.05% for ~30 days.
Installed on 1 functional locations
0 with criticality A/B · 200 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_BF-110 CRACKING FURNACE BF-110 | S | 200 | 41 | 14.58 |
Lead time and procurement
Lead time 58 ± 27 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 21 Sept 2026 | Medium | PX_BF-110 | Replace burner tip BF-110 |
| 17 Sept 2026 | Medium | PX_BF-110 | Install scaffolding at BF-110 |
| 15 Sept 2026 | Medium | PX_BF-110 | Decoking follow up BF-110 |
| 11 Sept 2026 | Medium | PX_BF-110 | Leak from packing |
| 03 Sept 2026 | Low | PX_BF-110 | Hot spot at convection BF-110 |
| 03 Sept 2026 | Medium | PX_BF-110 | Thermograph wall BF-110 |
| 01 Sept 2026 | Medium | PX_BF-110 | Replace burner tip BF-110 |
| 30 Aug 2026 | Low | PX_BF-110 | Leak from packing |
| 07 Aug 2026 | Medium | PX_BF-110 | Install scaffolding at BF-110 |
| 07 Aug 2026 | Medium | PX_BF-110 | Painting BF-110 |
Recent goods issues
Never issued in the 17-month history.