TUBE PLUG,EXCHANGER,MODEL AT252,NBR
Material 4100093343 · TUBE PLUG · Plant 1000
AReduceExcess
- Material
- 4100093343
- Category
- TUBE PLUG
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- A (32 of 43 FuncLocs A/B)
- Supplier
- CAHAYA INDUSTRI SENTOSA PT
- Lead time
- 51 d · P80 50 d
- Unit price
- Rp 217,969
Recommendation
- 1.Forecast 14 EA/year: 14 unplanned (recency-weighted compound poisson (own history)).
- 2.Lead time ~51 days; expected demand during lead time 1.9.
- 3.A 100.0% service level gives the lowest holding + downtime-risk cost: reorder at 9, order up to 23.
- 4.Stock 569 exceeds the level to keep (23) by 546.
- 5.Installed on 43 FuncLoc(s), 32 of them criticality A/B.
- 6.ML early warning: 94% probability of demand in the next 90 days.
ML early warningLast turnaround used 6Single source
On hand / on order
569 / 0
no open PO
Today Min / Max
8 / 17
static parameters in BoM
Rec. Min (reorder point)
9
safety stock 8
Rec. Max
23
order qty 14
Service level
100.0%
stockout risk now 0%
Unit price
Rp 217,969
PO history
ML early warning: 94% probability this part is needed in the next 90 days (above the 30% warning threshold). Inputs: 6 issue days in the last 180 days, last issue 21 days ago, 5 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 2 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (6 units) excluded from the baseline.
Demand pattern Intermittent · 16 issue days · method: Recency-weighted compound Poisson (own history).
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 7.0B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~29 days.
Installed on 43 functional locations
32 with criticality A/B · 55 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_HE-532B PROPYLENE COOLER | A | 1 | 4 | 1.50 |
| PX_HE-848C COOLING WATER CONDENSER | A | 1 | 4 | 1.08 |
| PX_HE-1074 C3 RECYCLE REBOILER | A | 1 | 3 | 1.08 |
| PX_HE-275C METHANOL TLE | A | 1 | 3 | 0.65 |
| PX_HE-693B ETHYLENE EXCHANGER | A | 3 | 3 | 1.08 |
| PX_HE-149A HYDROGEN COOLER | A | 1 | 2 | 0.65 |
| PX_HE-1917B DILUTION STEAM TLE | A | 1 | 2 | 1.08 |
| PX_HE-1768 GASOLINE EXCHANGER | A | 4 | 1 | 0.65 |
| PX_HE-234C REFLUX EXCHANGER | A | 1 | 1 | 0.22 |
| PX_HE-1108C INHIBITOR TLE | A | 1 | 0 | 0.22 |
| PX_HE-1797C FUEL OIL PREHEATER | A | 1 | 0 | 0.22 |
| PX_HE-1817C WASH WATER TLE | A | 1 | 0 | 0.22 |
Lead time and procurement
Lead time 51 ± 27 days (PO history, 7 PO lines) · on-time 42%
| PR date | Type | Qty | Unit price | Delivery | Lead time |
|---|---|---|---|---|---|
| 17 Aug 2026 | PR03 Regular replenishment | 4 | Rp 217,969 | 20 Sept 2026 | 34 d |
| 16 Apr 2026 | PR03 Regular replenishment | 6 | Rp 212,002 | 15 Jun 2026 | 60 d |
| 14 Mar 2026 | PR03 Regular replenishment | 9 | Rp 226,449 | 19 Apr 2026 | 36 d |
| 26 Jan 2026 | PR03 Regular replenishment | 7 | Rp 208,101 | 24 Feb 2026 | 29 d |
| 27 Nov 2025 | PR03 Regular replenishment | 10 | Rp 219,553 | 01 Jan 2026 | 35 d |
| 13 Sept 2025 | PR03 Regular replenishment | 8 | Rp 222,776 | 05 Nov 2025 | 53 d |
| 16 Jun 2025 | PR03 Regular replenishment | 3 | Rp 209,017 | 15 Jul 2025 | 29 d |
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 27 Sept 2026 | Medium | PX_HE-532B | Replace lamp as per PM finding |
| 24 Sept 2026 | Low | PX_HE-848C | HE-848C fouling |
| 22 Sept 2026 | Low | PX_HE-113D | Retubing HE-113D |
| 21 Sept 2026 | Medium | PX_HE-693B | Retubing HE-693B |
| 19 Sept 2026 | Medium | PX_HE-848C | Replace lamp as per PM finding |
| 06 Sept 2026 | High | PX_HE-193B | Install scaffolding at HE-193B |
| 19 Aug 2026 | Medium | PX_HE-113D | Install scaffolding at HE-113D |
| 12 Aug 2026 | Medium | PX_HE-981 | Install scaffolding at HE-981 |
| 04 Aug 2026 | Medium | PX_HE-275C | Painting HE-275C |
| 02 Jul 2026 | Low | PX_HE-1074 | Install scaffolding at HE-1074 |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 10 Sept 2026 | 1 | 201000038057 | Corrective |
| 21 Aug 2026 | 2 | 201000007325 | Corrective |
| 20 Aug 2026 | 1 | 201000007325 | Corrective |
| 17 Jun 2026 | 1 | 201000020554 | Corrective |
| 08 Jun 2026 | 1 | 201000039784 | Corrective |
| 24 Apr 2026 | 1 | 201000023719 | Corrective |
| 25 Jan 2026 | 2 | 201000021700 | Corrective |
| 05 Jan 2026 | 1 | 201000017531 | Corrective |
| 04 Jan 2026 | 1 | 201000017531 | Corrective |
| 25 Dec 2025 | 1 | 201000035080 | Corrective |
| 24 Dec 2025 | 2 | 203000033370 | Turnaround |
| 20 Dec 2025 | 1 | 203000033370 | Turnaround |
| 19 Dec 2025 | 1 | 203000033370 | Turnaround |
| 19 Dec 2025 | 2 | 203000033370 | Turnaround |
| 04 Dec 2025 | 1 | 201000014476 | Corrective |