Sparely
DU

TUBE PLUG,EXCHANGER,SIZE GP114,A105

Material 4100094075 · TUBE PLUG · Plant 1000

AReorderCriticalStockout
Material
4100094075
Category
TUBE PLUG
Base unit
EA
MRP type
Non Stock
Criticality
A (1 of 1 FuncLocs A/B)
Supplier
No PO history
Lead time
77 d · P80 151 d
Unit price
Rp 505,158 (est.)

Recommendation

  • 1.Forecast 0.9 EA/year: 0.9 unplanned (credibility blend: own history + installed-base prior).
  • 2.Lead time ~77 days; expected demand during lead time 0.2.
  • 3.A 100.0% service level gives the lowest holding + downtime-risk cost: reorder at 3, order up to 4.
  • 4.On hand 0 + on order 0 is at or below the reorder point: order 4 now.
  • 5.Installed on 1 FuncLoc(s), 1 of them criticality A/B.
Proposed purchase requisition
4 EA
Rp 2.0M · order by 01 Oct 2026
Expected arrival ≈ 77 days
Price estimatedLead time estimated
On hand / on order
0 / 0
no open PO
Today Min / Max
0 / 0
static parameters in BoM
Rec. Min (reorder point)
3
safety stock 3
Rec. Max
4
order qty 1
Service level
100.0%
stockout risk now 17%
Unit price
Rp 505,158
Category + unit estimate
ML early warning: 2% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue 211 days ago, 0 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.

Consumption history and 12-month forecast

Units per month. Turnaround issues (0 units) excluded from the baseline.

Demand pattern Single issue · 1 issue days · method: Credibility blend: own history + installed-base prior.

Cost of each service level

Annual holding vs downtime-risk cost for this part

Not stocking at all would cost Rp 568.1M/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~29 days.

Installed on 1 functional locations

1 with criticality A/B · 1 units installed

FuncLocCrit.InstalledNotificationsFailures / yr
PX_HE-1334B
BOTTOM CONDENSER
A182.36

Lead time and procurement

Lead time 77 ± 62 days (Category estimate, 0 PO lines) · on-time –

No purchase history: price and lead time are estimated from parts of the same category.

Planned maintenance demand (next 12 months)

No part-consuming maintenance job uses this part in the next 12 months.

Recent notifications on its equipment

DatePriorityFuncLocDescription
28 Aug 2026MediumPX_HE-1334BInstall scaffolding at HE-1334B
07 May 2026MediumPX_HE-1334BInstall scaffolding at HE-1334B
29 Mar 2026MediumPX_HE-1334BHE-1334B tube leak
01 Mar 2026MediumPX_HE-1334BHE-1334B fouling
13 Feb 2026MediumPX_HE-1334B[MSI-B-26-MEX-353] Permanent repair
10 Feb 2026LowPX_HE-1334BLeak from packing
28 Nov 2025EmergencyPX_HE-1334BHE-1334B tube leak
17 May 2025LowPX_HE-1334BLeak from packing

Recent goods issues

Posting dateQtyOrderOrder type
04 Mar 20261201000026555Corrective