NOZZLE,SAFETY VALVE,DWG.750-8988,FOR PRV
Material 4300008803 · NOZZLE · Plant 1000
SSafety-criticalReorderNormalSlow-moving
- Material
- 4300008803
- Category
- NOZZLE
- Base unit
- EA
- MRP type
- Stock Item
- Criticality
- S (0 of 1 FuncLocs A/B, 1 safety/shutdown valve)
- Supplier
- No PO history
- Lead time
- 121 d · P80 177 d
- Unit price
- Rp 20.3M (est.)
Recommendation
- 1.Safety-critical element: installed on 1 safety or shutdown valve location(s) (equipment criticality S). Downtime risk is costed as class A and at least 1 spare is always kept; any reduction needs Management sign-off.
- 2.Forecast 1.7 EA/year: 1.7 unplanned (credibility blend: own history + installed-base prior).
- 3.Lead time ~121 days; expected demand during lead time 0.6.
- 4.A 99.7% service level gives the lowest holding + downtime-risk cost: reorder at 4, order up to 6.
- 5.On hand 2 + on order 0 is at or below the reorder point: order 4 now.
Proposed purchase requisition
4 EA
Rp 81.1M · order by 01 Oct 2026
Expected arrival ≈ 121 days
Safety-critical (SCE)Price estimatedLead time estimated
On hand / on order
2 / 0
no open PO
Today Min / Max
1 / 3
static parameters in BoM
Rec. Min (reorder point)
4
safety stock 4
Rec. Max
6
order qty 2
Service level
99.7%
stockout risk now 3%
Unit price
Rp 20.3M
Category + unit estimate
ML early warning: 4% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue 231 days ago, 1 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.
Consumption history and 12-month forecast
Units per month. Turnaround issues (0 units) excluded from the baseline.
Demand pattern Single issue · 1 issue days · method: Credibility blend: own history + installed-base prior.
Cost of each service level
Annual holding vs downtime-risk cost for this part
Not stocking at all would cost Rp 1.3B/yr in expected downtime and emergency buys. A stockout here stops production with probability 1.07% for ~69 days.
Installed on 1 functional locations
0 with criticality A/B · 1 units installed
| FuncLoc | Crit. | Installed | Notifications | Failures / yr |
|---|---|---|---|---|
| PX_PRV-489B SAFETY VALVE PP-1106A | S | 1 | 7 | 2.18 |
Lead time and procurement
Lead time 121 ± 50 days (Category estimate, 0 PO lines) · on-time –
No purchase history: price and lead time are estimated from parts of the same category.
Planned maintenance demand (next 12 months)
No part-consuming maintenance job uses this part in the next 12 months.
Recent notifications on its equipment
| Date | Priority | FuncLoc | Description |
|---|---|---|---|
| 15 Sept 2026 | Low | PX_PRV-489B | Repair insulation PRV-489B |
| 10 Jun 2026 | Low | PX_PRV-489B | PRV-489B simmering |
| 13 Dec 2025 | Medium | PX_PRV-489B | Recertification PRV-489B |
| 20 Oct 2025 | High | PX_PRV-489B | Leak from packing |
| 08 Oct 2025 | Low | PX_PRV-489B | Install scaffolding at PRV-489B |
| 29 Sept 2025 | Medium | PX_PRV-489B | PRV-489B passing |
| 09 May 2025 | Medium | PX_PRV-489B | Recertification PRV-489B |
Recent goods issues
| Posting date | Qty | Order | Order type |
|---|---|---|---|
| 12 Feb 2026 | 2 | 201000019526 | Corrective |