Sparely
DU

TRAY VALVE,DWG.661-4133,FOR CL-1165

Material 4300020106 · TRAY VALVE · Plant 1000

SMonitorInsurance gap
Material
4300020106
Category
TRAY VALVE
Base unit
EA
MRP type
Non Stock
Criticality
S (0 of 1 FuncLocs A/B)
Supplier
MITRA ENERGI PERSADA PT
Lead time
97 d · P80 104 d
Unit price
Rp 107,703

Recommendation

  • 1.Forecast 0.1 EA/year: 0.1 unplanned (installed-base failure prior (no history)).
  • 2.Lead time ~97 days; expected demand during lead time 0.0.
  • 3.A 98.7% service level gives the lowest holding + downtime-risk cost: reorder at 0, order up to 1.
  • 4.Never issued in 17 months: review with reliability engineering before buying an insurance spare.
Insurance spare candidateSingle source
On hand / on order
0 / 0
no open PO
Today Min / Max
0 / 0
static parameters in BoM
Rec. Min (reorder point)
0
safety stock 0
Rec. Max
1
order qty 1
Service level
98.7%
stockout risk now 1%
Unit price
Rp 107,703
PO history
ML early warning: 2% probability this part is needed in the next 90 days (below the 30% warning threshold). Inputs: 0 issue days in the last 180 days, last issue never, 0 failure notifications on its equipment in 90 days, 0 planned jobs in 90 days, 0 PRs in 180 days.

Consumption history and 12-month forecast

Units per month. Turnaround issues (0 units) excluded from the baseline.

Demand pattern No demand · 0 issue days · method: Installed-base failure prior (no history).

Cost of each service level

Annual holding vs downtime-risk cost for this part

Not stocking at all would cost Rp 116,145/yr in expected downtime and emergency buys. A stockout here stops production with probability 0.05% for ~30 days.

Installed on 1 functional locations

0 with criticality A/B · 1 units installed

FuncLocCrit.InstalledNotificationsFailures / yr
PX_CL-1165
HYDROGEN TOWER
S151.23

Lead time and procurement

Lead time 97 ± 25 days (PO history + category, 1 PO lines) · on-time 24%

PR dateTypeQtyUnit priceDeliveryLead time
04 Nov 2025PR06
Regular replenishment
1Rp 107,70330 Apr 2026177 d

Planned maintenance demand (next 12 months)

No part-consuming maintenance job uses this part in the next 12 months.

Recent notifications on its equipment

DatePriorityFuncLocDescription
13 Jan 2026HighPX_CL-1165Install scaffolding at CL-1165
07 Dec 2025MediumPX_CL-1165Replace lamp as per PM finding
01 Dec 2025MediumPX_CL-1165Install scaffolding at CL-1165
27 Sept 2025MediumPX_CL-1165CL-1165 DP high
03 Aug 2025LowPX_CL-1165Install scaffolding at CL-1165

Recent goods issues

Never issued in the 17-month history.